Federal Awards · Award

AWARDED IAW QUOTE DATED 11-16-2009, SOLICITATION NUMBER QSDLAD-E3-10-1205-TO DATED 11-13-09, IPD IS HEREBY…

Award details are derived from public USAspending.gov records. Not a bid recommendation.

Award details

Award ID
GSFPNE9J6509
Contractor
Sub-agency / office
Federal Acquisition Service
Award amount
$0
Period of performance
Nov 19, 2009 – Dec 21, 2009
NAICS
333319
PSC
PSC 7910
Place of performance
ID

Public award description

AWARDED IAW QUOTE DATED 11-16-2009, SOLICITATION NUMBER QSDLAD-E3-10-1205-TO DATED 11-13-09, IPD IS HEREBY INCORPORATED BELOW AND MADE PART OF THIS AWARD. NSN: 7910-00-267-1205 CLEANER, VACUUM, ELECTRIC: SHALL BE A PORTABLE, HAND HELD, INDUSTRIAL TYPE, BLOWER-SUCTION UNIT. SHALL BE IN ACCORDANCE WITH COMMERCIAL ITEM DESCRIPTION A-A-50438, DATED MARCH 26, 1991. TYPE HV1 - HIGH VELOCITY VOLTAGE - 115 VAC, 60 HZ, AND 115 VDC CORD - 50 FT. SHOULDER STRAP - INCLUDED ATTACHMENTS - INCLUDED (SEE TABLE II OF A-A-50438) PORTABLE HAND HELD VACUUM/BLOWER UNIT OF ISSUE SHALL BE EA (ONE COMPLETE SYSTEM TO A PACKAGE). EXCEPTIONS TO THE SPECIFICATION: UNDER THE " ABSTRACT." PARAGRAPH, IMMEDIATELY AFTER THE SENTENCE ENDING WITH " ...SHALL BE OF THE FOLLOWING TYPES:" DELETE THE REMAINDER OF THE PARAGRAPH, AND SUBSTITUTE THE FOLLOWING: TYPE HV1 - HIGH VELOCITY, SHALL FUNCTION ON 115 VAC, 60 HZ, AND 115 VDC. TYPE LV1 - LOW VELOCITY, SHALL FUNCTION ON 115 VAC, 60 HZ, AND 115 VDC. TYPE MV1 - MEDIUM VELOCITY, SHALL FUNCTION ON 115 VAC, 60 HZ, AND 115 VDC. TYPE MV2 - MEDIUM VELOCITY, SHALL FUNCTION ON 220 VAC, 50 HZ, AND 220 VDC. UNDER " SALIENT CHARACTERISTICS.," DELETE PARAGRAPH 5, AND SUBSTITUTE THE FOLLOWING: 5. AT NORMAL FULL LOAD OPERATING CONDITIONS, RADIATED EMISSIONS SHALL BE IN COMPLIANCE WITH THE LIMITS SPECIFIED BY MIL-STD-461 RE102 WITH THE FOLLOWING EXCEPTIONS TO THE LIMIT CURVE: FREQUENCY RANGE MAXIMUM PERMISSIBLE DB V/M 34 TO 38 MHZ 42.5 225 TO 250 MHZ 46.6 AT NORMAL FULL LOAD OPERATING CONDITIONS, CONDUCTED EMISSIONS SHALL BE IN COMPLIANCE WITH THE LIMITS SPECIFIED BY MIL-STD-461 CE101 WITH THE FOLLOWING EXCEPTIONS TO THE LIMIT CURVE: FREQUENCY RANGE MAXIMUM PERMISSIBLE DB A 135 TO 170 HZ 120.5 2.75 KHZ TO 2.85 KHZ 90 5.7 KHZ TO 6.5 KHZ 93 AT NORMAL FULL LOAD OPERATING CONDITIONS, CONDUCTED EMISSIONS SHALL BE IN COMPLIANCE WITH THE LIMITS SPECIFIED BY MIL-STD-461 CE102 WITH THE FOLLOWING EXCEPTION TO THE LIMIT CURVE: FREQUENCY RANGE MAXIMUM PERMISSIBLE DB V 17.8 KHZ TO 18.2 KHZ 95.5 THE MOUNTING OF THE NOISE SUPPRESSION ACCESSORIES SHALL BE SUCH THAT AN ELECTRICAL SHOCK HAZARD IS NOT INTRODUCED. THE USE OF LINE-TO-GROUND FILTERS FOR EMI CONTROL SHALL BE MINIMIZED. SUCH FILTERS ESTABLISH LOW IMPEDANCE PATHS FOR STRUCTURE (COMMON-MODE) CURRENTS THROUGH THE GROUND PLANE AND CAN BE A MAJOR CAUSE OF INTERFERENCE IN SYSTEMS, PLATFORMS, OR INSTALLATIONS, BECAUSE THE CURRENTS CAN COUPLE INTO OTHER EQUIPMENTS USING THE SAME GROUND PLANE. IF SUCH A FILTER MUST BE EMPLOYED, THE TOTAL LINE-TO-GROUND CAPACITANCE SHALL NOT EXCEED 0.1 ?F FOR 60 HZ EQUIPMENT AND 0.02 ?F FOR 400 HZ EQUIPMENT. THE FILTERING EMPLOYED SHALL BE FULLY DESCRIBED IN THE EQUIPMENT OR SUBSYSTEM TECHNICAL MANUAL AND THE ELECTROMAGNETIC INTERFERENCE CONTROL PROCEDURES (EMICP). UNDER " SALIENT CHARACTERISTICS.," ADD A NEW PARAGRAPH AS FOLLOWS: 13. TYPES HV1, LV1, AND MV1 SHALL BE CAPABLE OF MEETING THE MINIMUM AIR DISCHARGE REQUIREMENTS OF TABLE I WHEN TESTED AT NORMAL FULL LOAD OPERATING CONDITIONS AT 115 VDC AND 115 VAC, 60 HZ. TYPE MV2 SHALL BE CAPABLE OF MEETING THE MINIMUM AIR DISCHARGE REQUIREMENT OF TABLE I WHEN TESTED AT NORMAL FULL LOAD OPERATING CONDITIONS AT 220 VDC, AND 220 VAC, 50 HZ. THE VOLUMETRIC AIR DISCHARGE SHALL BE DETERMINED BY MULTIPLYING THE AVERAGE DISCHARGE VELOCITY BY THE AREA OF THE ORIFICE. THE AVERAGE DISCHARGE VELOCITY IS OBTAINED BY MEANS OF A PITOT TUBE, OR EQUIVALENT, PLACED WITHIN 2 INCHES OF THE OUTLET; THE NUMBER AND ARRANGEMENT OF THE TUBE POSITIONS SHALL BE SUFFICIENT TO DETERMINE THE AVERAGE VELOCITY AT THE DISCHARGE. DELETE " CONTRACTOR CERTIFICATION" PARAGRAPH, SUBSTITUTE THE FOLLOWING: PRODUCT CONFORMANCE: THE PRODUCTS PROVIDED SHALL MEET THE SALIENT CHARACTERISTICS OF THIS PURCHASE DESCRIPTION, CONFORM TO THE PRODUCER S OWN DRAWINGS, SPECIFICATIONS, STANDARDS, AND QUALITY ASSURANCE PRACTICES AND BE THE SAME PRODUCT OFFERED FOR SALE IN THE COMMERCIAL MARKET. TH

Source: USAspending.gov

Find out who's winning similar federal contracts

Discover comparable awards, related contractors, and agency purchasing history.

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. Click Gemini to copy the research question when your browser allows, or use Copy question.