Federal Awards · Award

IGF::CT::IGF THE CONTRACTOR SHALL PROVIDE ALL SUPERVISION, LABOR, MATERIALS AND EQUIPMENT TO PROVIDE 3-YEAR…

Award details are derived from public USAspending.gov records. Not a bid recommendation.

Award details

Award ID
GSP0913WA0010
Contractor
Sub-agency / office
Public Buildings Service
Award amount
$0
Period of performance
Mar 27, 2013 – Jun 30, 2013
NAICS
561210 — Facilities Support Services
Place of performance
CA
Parent award
GS09P04KSC0030

Public award description

IGF::CT::IGF THE CONTRACTOR SHALL PROVIDE ALL SUPERVISION, LABOR, MATERIALS AND EQUIPMENT TO PROVIDE 3-YEAR TESTING OF ALL MAIN CIRCUIT BREAKERS IN ACCORDANCE WITH THE CONTRACT TERMS IN OUTLINED PARAGRAPHS: C.6 3-YEAR ELECTRICAL INSPECTIONS, TESTING AND MAINTENANCE: ELECTRICAL, TESTING AND MAINTENANCE OF THE TYPE REQUIRED EVERY THREE YEARS BY THE PUBLIC BUILDINGS MAINTENANCE GUIDES AND TIME STANDARDS (GUIDES E-26,27,28,20,30A,37, 37A,57) SHALL AS A MIMIMUM FOLLOW NETA MAINTENACE TESTING SPECIFICATION FOR ELECTRICAL POWER DISTRIBUTION EQUIPMENT AND SYSTEMS (1997). THE NETA STANDARD SHALL TAKE PRECENDENCE WHERE IT CONFLICTS WITH THE GUIDES. AN INDEPENDENT TESTING FIRM, MEETING THE STANDARDS OF THE NETA SHALL BE HIRED TO PERFORM THE SERVICE. DURING THE YEAR WHEN THE THREE YEAR INSPECTION AND TESTING IS REQUIRED, ELECTRICAL INSPECTION AND TESTING REQUIRED ON AN ANNUAL AND SEMIANNUAL BASIS BY THE PUBLIC BUILDINGS MAINTENANCE GUIDES AND TIME STANDARDS GUIDES SHALL BE PERFORMED BY THE INDEPENDENT TESTING FIRMS, ALSO FOLLOWING THE NETA STANDARDS. A COMPREHENSIVE REPORT OF INSPECTION AND TESTING FINDINGS SHALL BE SUBMITTED WITHIN 10 WORKING DAYS OF COMPLETION OF THE INSPECTION AND TESTING. RECOMMENDATIONS TO REPLACE OR UPGRADE ELECTRICAL EQUIPMENT IN THE REPORT SHALL NOT GENERATE LIABILITY FOR REPAIRS TO THE CONTRACTOR, UNLESS DETERIORATION OF EQUIPMENT IS CAUSED BY MAINTENANCE OR OPERATIONAL ERRORS OR OMISSIONS BY THE CONTRACTOR. C.7 EXERCISE OF ELECTRICAL BREAKERS: IN ADDITION TO ANY OTHER MAINTENANCE AND TESTING REQUIREMENTS, ALL ELECTRICAL BREAKERS, REGARDLESS OF SIZE, SHALL BE EXERCISED NOT LESS FREQUENTLY THAN ANNUALLY. C.8 THERMOGRAPHIC ANALYSIS OF ELECTRICAL BREAKERS: ALL ELECTRICAL BREAKERS IN THE BUILDING MUST BE TESTED THROUGH THERMOGRAPHIC ANALYSIS AT THE TIME TESTING IS PERFORMED ON SWITCH GEAR (EVERY THREE YEARS).

Source: USAspending.gov

Find out who's winning similar federal contracts

Discover comparable awards, related contractors, and agency purchasing history.

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. Click Gemini to copy the research question when your browser allows, or use Copy question.