Federal Awards · Award

THE HARSH RADIATION ENVIRONMENT ANTICIPATED DURING THE EUROPA JUPITER SYSTEM MISSION (EJSM) PRESENTS A SIGN…

Award details are derived from public USAspending.gov records. Not a bid recommendation.

Award details

Award ID
NNX11CF29P
Contractor
Sub-agency / office
National Aeronautics and Space Administration
Award amount
$0
Period of performance
Jul 21, 2011 – Sep 29, 2011
NAICS
541712 — Research and Development in the Physical, Engineering, and Life Sciences
PSC
PSC AR11
Place of performance
CA

Public award description

THE HARSH RADIATION ENVIRONMENT ANTICIPATED DURING THE EUROPA JUPITER SYSTEM MISSION (EJSM) PRESENTS A SIGNIFICANT CHALLENGE TO DEVELOP RADIATION-HARDENED NOTIONAL INSTRUMENTS. A HIGH-PERFORMANCE, RADIATION-TOLERANT DETECTOR IS REQUIRED FOR THE TIME-OF-FLIGHT LASER ALTIMETER SYSTEM ON THE JUPITER EUROPA ORBITER (JEO), WHICH WILL PERFORM CRITICAL CHARACTERIZATION OF EUROPA'S TOPOGRAPHY, OCEAN TIDES, AND ICE SHELF. AVALANCHE PHOTODIODES (APDS) ARE CONVENTIONALLY CHOSEN AS DETECTORS FOR STANDARD LASER ALTIMETER SYSTEMS. HOWEVER, THE PERFORMANCE OF APDS DEGRADES SIGNIFICANTLY AFTER EXPOSURE TO HIGH LEVELS OF RADIATION. AERIUS PHOTONICS PROPOSES TO DEVELOP A NOVEL RADIATION-TOLERANT DETECTOR THAT IS SUITABLE FOR USE IN SPACE-BASED LASER-ALTIMETER SYSTEMS BY INTEGRATING A VERTICAL-CAVITY SEMICONDUCTOR OPTICAL AMPLIFIER (VCSOA) WITH A PIN PHOTODETECTOR. THE RESULTING DEVICE, KNOWN AS A VERTICAL-CAVITY AMPLIFYING DETECTOR (VCAD), IS EXPECTED TO PROVIDE HIGH-GAIN, HIGH-SPEED, LOW-NOISE DETECTION AND DEMONSTRATE SIGNIFICANT IMPROVEMENTS IN RADIATION TOLERANCE OVER APDS. THE OPTICAL PREAMPLIFICATION PROVIDED BY THE VCSOA, ALONG WITH ITS OPERATION AS A FORWARD-BIASED MAJORITY-CARRIER DEVICE, RENDERS THE VCAD SYSTEM INSENSITIVE TO RADIATION-INDUCED INCREASES IN DETECTOR DARK CURRENT NOISE AND RECEIVER ELECTRONICS NOISE. THE VCAD IS ALSO EXPECTED TO BE SIGNIFICANTLY LESS SUSCEPTIBLE TO SINGLE EVENT TRANSIENTS (SETS) THAN AN APD. AERIUS PHOTONICS HAS EXPERTISE IN VCSOA DEVELOPMENT AND HAS ALREADY DEMONSTRATED BASIC RADIATION TOLERANCE OF VCSOAS TO 300 KRAD WITH GAMMA RADIATION AND TO 300 KRAD WITH 63 MEV PROTONS. IN PHASE I OF THIS PROGRAM, AERIUS WILL DESIGN, FABRICATE AND CHARACTERIZE VCADS THAT HAVE BEEN EXPOSED TO A MORE COMPREHENSIVE RADIATION TEST PLAN THAT WILL INCLUDE CONDITIONS ANTICIPATED ON THE EJSM.

Source: USAspending.gov

Find out who's winning similar federal contracts

Discover comparable awards, related contractors, and agency purchasing history.

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. Click Gemini to copy the research question when your browser allows, or use Copy question.