Federal Awards · Award

IGF::OT::IGF AN ON-BOARD OXYGEN CONCENTRATOR IS REQUIRED DURING LONG DURATION MANNED SPACE MISSIONS TO SUPP…

Award details are derived from public USAspending.gov records. Not a bid recommendation.

Award details

Award ID
NNX14CC55P
Contractor
Sub-agency / office
National Aeronautics and Space Administration
Award amount
$0
Period of performance
Jun 20, 2014 – Dec 19, 2014
NAICS
541712 — Research and Development in the Physical, Engineering, and Life Sciences
PSC
PSC AR11
Place of performance
CO

Public award description

IGF::OT::IGF AN ON-BOARD OXYGEN CONCENTRATOR IS REQUIRED DURING LONG DURATION MANNED SPACE MISSIONS TO SUPPLY MEDICAL OXYGEN. THE COMMERCIAL MEDICAL OXYGEN GENERATORS BASED ON PRESSURE SWING ADSORPTION (PSA) ARE LARGE AND HIGHLY POWER INTENSIVE. TDA RESEARCH, INC. (TDA) PROPOSES TO DEVELOP A SMALL, LIGHTWEIGHT, PORTABLE OXYGEN GENERATOR BASED ON A VACUUM SWING ADSORPTION (VSA) TO PRODUCE CONCENTRATED MEDICAL OXYGEN. THE UNIT USES AMBIENT VEHICLE CABIN AIR AS THE FEED AND DELIVERS HIGH PURITY OXYGEN WHILE MEETING NASA'S REQUIREMENTS FOR HIGH FLOW CAPACITY, CLOSED-LOOP TISSUE OXYGEN CONTROL AND OPERATION IN MICROGRAVITY/PARTIAL GRAVITY. TDA'S VSA SYSTEM USES A MODIFIED VERSION OF THE LITHIUM EXCHANGED LOW SILICA X ZEOLITE (LI-LSX), A STATE-OF-THE-ART AIR SEPARATION SORBENT EXTENSIVELY USED IN COMMERCIAL PORTABLE OXYGEN CONCENTRATORS (POCS) TO ENHANCE THE N2 ADSORPTION CAPACITY. IN PHASE I, WE WILL DEMONSTRATE THE SCIENTIFIC, TECHNICAL, AND COMMERCIAL FEASIBILITY OF THE OXYGEN CONCENTRATOR MODULE (OCM). THE CONCENTRATOR WILL HAVE AN ADJUSTABLE PRESSURE OUTPUT TO PRODUCE 2-15 LPM OF O2 AT 50 PERCENT TO MORE THAN 90 PERCENT PURITY FROM AMBIENT CABIN AIR. THE OCM WILL BE CAPABLE OF SELF-REGULATING THE OXYGENATION OF THE PATIENT USING A CLOSED LOOP FEEDBACK SYSTEM THAT SENSES TISSUE OXYGENATION LEVEL. WE WILL EVALUATE THE SORBENT PERFORMANCE IN A BREADBOARD BENCH-SCALE PROTOTYPE UNDER SIMULATED MICROGRAVITY/PARTIAL GRAVITY EXPLORATION ATMOSPHERES AND CARRY OUT A 10,000 CYCLE TEST (AT A MINIMUM) TO DETERMINE ITS LONG-TERM PERFORMANCE AND MECHANICAL DURABILITY. BASED ON THE EXPERIMENTAL RESULTS, WE WILL CARRY DESIGN THE DEMONSTRATION UNIT, OPTIMIZE ITS POWER DRAW OVER THE RANGE OF FLOWS AND OXYGEN LEVELS, AND DETERMINE ITS WEIGHT, VOLUME AND HEAT REJECTION REQUIREMENTS. THIS DESIGN WILL ALSO INCLUDE AN INLET FILTER DESIGNED TO REMOVE POTENTIAL SMOKE OR TOXIC GASES.

Source: USAspending.gov

Find out who's winning similar federal contracts

Discover comparable awards, related contractors, and agency purchasing history.

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. Click Gemini to copy the research question when your browser allows, or use Copy question.