UNIT TOTAL ITEM DESCRIPTION QTY UNIT COST COST ------------------------------------------------------------…
Award details are derived from public USAspending.gov records. Not a bid recommendation.
Award details
- Award ID
- V640C04540
- Contractor
- Awarding agency
- Department of Veterans Affairs
- Sub-agency / office
- Department of Veterans Affairs
- Award amount
- $0
- Period of performance
- Feb 12, 2010 – Jun 12, 2010
- NAICS
- 332410 — Power Boiler and Heat Exchanger Manufacturing
- Place of performance
- CA
Public award description
UNIT TOTAL ITEM DESCRIPTION QTY UNIT COST COST -------------------------------------------------------------------------------- 1 ****SERVICE REQUEST*** 1 JB 4200.00 4200.00 JOB: REPLACEMENT OF #1 BOILER'S MODULATING MOTOR AT THE LIVERMORE DIVISION OF THE VAPAHC. SERVICE CONTRACTOR WILL PROVIDE ALL LABOR AND MATERIALS NEEDED TO REPLACE EXISTING NON-FUNCTIONING HAYS CLEVELAND BOILER MODULATING CONTROL WITH A HONEYWELL MODULATING MOTOR CONTROL MODEL M9484F1031 THAT HAS THE REQUIRED 2 END SWITCHES 5-54 DEGREE ADJUSTABLE, TORQUE ENTER '^' TO HALT: UNIT TOTAL ITEM DESCRIPTION QTY UNIT COST COST -------------------------------------------------------------------------------- AND TRAVEL AS THE FACTORY MOD MOTOR. CONTRACTOR WILL LEAVE THE OLD HAYS CLEVELAND MOTOR AND END WITH PLANT OPERATOR FOR PLANT SPARE PARTS. CONTRACTOR WILL HOOK-UP THE NEW MODULATING MOTOR TO THE EXISTING D-8 AND M-D HIGH FIRE PURGE AND LOW FIRE START CIRCUITS, THEN TESTING ELECTRICALLY BEFORE FIRING THE BOILER. CONTRACTOR WILL TEST AND CONFIRM OPERATIONAL COMPATIBILITY OF THE EXISTING SUB MASTER CONTROLLER AND THE NEW MODULATING MOTOR. ENTER '^' TO HALT: UNIT TOTAL ITEM DESCRIPTION QTY UNIT COST COST -------------------------------------------------------------------------------- CONTRACTOR WILL UPDATE THE PLANT MASTER SCHEMATIC DRAWINGS TO REFLECT CHANGES MADE AS A RESULT OF THE NEW MODULATING MOTOR INTERFACE WITH EXISTING SYSTEM OPERATION. CONTRACTOR WILL NOT DISTURB THE FIRING POINTS ADJUSTMENTS OF THE GAS AND FUEL OIL VALVES AND LINKAGES. IF A DISTURBANCE OF FIRING POINTS OCCURS THE COTR WILL BE NOTIFIED IN ORDER TO ADDRESS WHAT FURTHER ACTION MAY BE NEEDED, SUCH AS RETUNING THE ENTER '^' TO HALT: UNIT TOTAL ITEM DESCRIPTION QTY UNIT COST COST -------------------------------------------------------------------------------- BOILER. COST ADJUSTMENT MAY BE REQUIRED. CONTRACTOR WILL CHECK THE COMBUSTION WITH A PORTABLE TESTER TO CONFIRM THE FIRING O2 LEVELS FOR PROPER OPERATION OF THE OXYMIZER LOW O2 ALARM CIRCUITS. BOC: 2520 FMS LINE: 001
Find out who's winning similar federal contracts
Discover comparable awards, related contractors, and agency purchasing history.
Related intelligence
- Agency: Department of Veterans Affairs
- PSC R499 — Support — Professional: Other
- Federal market intelligence software