Public award description

1) CONTRACTOR SHALL PROVIDE ALL REQUIRED MATERIALS AND LABOR TO INSTALL A COMPLETE OPERATIONAL VEHICLE EXHAUST SYSTEM AT BUILDING 113 FIRE HOUSE GARAGE AT THE CASTLE POINT CAMPUS. 2) CONTRACTOR SHALL SUPPLY A PLYMO VENT SBTA-31B BACK IN TRACK SYSTEM OR EQUIVALENT SERVING UP FIVE (5) EMERGENCY VEHICLES. UNIT SHALL INCLUDE THE FOLLOWING ACCESSORIES: A. ENGINE SENSOR SWITCHES: THAT ACTIVATE AN AUTOMATIC TIMER TO START THE SYSTEM EXHAUST FAN. THE FAN SHALL OPERATE VIA AN ADJUSTABLE TIMER AND CAN BE SET UP TO FIVE MINUTES MINIMUM. THESE SENSORS SHALL BE ACTIVATED THROUGH AIR MOVEMENT WITHIN THE EXHAUST DUCT WORK. ADDITIONALLY THESE SENSOR SHALL BE HARD WIRED TO THE CONTROL BOX ENSURING POWER IS SUPPLIED TO THE SENSOR. B. GRABBER NOZZLE: A PNEUMATIC NOZZLE ATTACHMENT WHICH INFLATES TO THE EMERGENCY VEHICLE EXHAUST PIPE FROM 1 6 IN DIAMETER PROVIDING A POSITIVE SEAL ELIMINATING ANY EXHAUST LEAK FROM THE CONNECTION. C. TRACK MOUNTED CONTROL VALVE: A RELEASE VALVE TO RELEASE AIR FROM THE BLADDER WHEN ACTIVATED BY A TRIP PLATE ON THE TROLLEY TO ENSURE EXHAUST SYSTEM DISCONNECTS SAFETY DURING EMERGENCY VEHICLE EXITING THE GARAGE. D. EXHAUST FAN/MOTOR: SHALL CONSIST OF A DIRECT DRIVE SPARK RESISTANT BLOWER PROVIDING ADEQUATE EXHAUST VELOCITIES TO PROPERLY CAPTURE AND REMOVE VEHICLE EXHAUST. 3500 FEET PER MINUTE (FPM) MINIMUM CONVEYING VELOCITY AND 5500 FPM FOR CAPTURE VELOCITY. EXHAUST SHALL ALSO HAVE A MINIMUM EXHAUST RATING OF 2850 CFM (CUBIC FEET PER MINUTE) AT 6 S.P. (STATIC PRESSURE). E. EXHAUST HOSE CONSTRUCTION: SHALL BE OF SUBSTANTIAL CONSTRUCTION TO HANDLE MULTIPLE DAILY DISCONNECTIONS AND RECONNECTIONS TO THE EMERGENCY VEHICLE. THE HOSE SHALL ALSO HAVE A RATING OF 400 DEGREE FAHRENHEIT ( F) CONTINUOUS OPERATION AND A 500 F INTERMITTENT TEMPERATURE RATINGS. HOSE DIAMETER SHALL BE SIZED TO ALLOW PROPER CONNECTION AND FLOW FROM THE EMERGENCY VEHICLE TO THE EXHAUST FAN/BLOWER.

Source: USAspending.gov

Find out who's winning similar federal contracts

Discover comparable awards, related contractors, and agency purchasing history.

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. Click Gemini to copy the research question when your browser allows, or use Copy question.