SAM.gov listing

B533--VANIHCS SPS Water Testing (VA-27-00000760)

Veterans Affairs, Department Of.250-network Contract Office 10 (36c250)PresolicitationSolicitation 36C25027R0012

Response deadline

Wed, Nov 4, 2026, 3:00 PM EST

Product Service Code

PSC B533
Analyze This Opportunity in CaptureIQ

Compare your company's capabilities against this federal opportunity using CaptureIQ.

Ready to Pursue This Opportunity?

Qualify the fit, analyze competitors, identify teaming partners, and generate review-ready materials — all in CaptureIQ.

  • Federal capture workflow
  • Competitor & teaming intelligence
  • Proposal preparation

Opportunity details

NAICS
541380
Notice type
Presolicitation
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Original posted
October 4, 2026
Last updated
October 17, 2026
Notice ID
b809bef3decb4239aea75927aa48483e

Summary

MODIFICATION STATEMENT OF WORK Sterile Processing Service ST-108 Testing Requirements Upgrade The contractor shall provide all the following for testing the water for/within SPS per the ANSI/AAMI ST108:2023 at the Marion, Fort Wayne, and Jackie Walorski VA sites as defined in this Statement of Work (SOW). WORK TO BE PERFORMED: Contractor shall provide all labor, materials, equipment, transportation, lodging, and supervision necessary to collect appropriate samples and deliver to a lab meeting the requirements for processing of AAMI ST108. Contractor shall calibrate the conductivity/resistivity meter monthly during their testing visit and provide a water analysis report. The contractor will be part of the multidisciplinary team that assists the water working group with resolving out-of-range water testing, in addition to: Serves as the subject matter expert on water testing per the ST108:2023 Serves as the subject matter expert on corrective actions to mitigate risks for out-of-range water testing parameters. Completes monthly, quarterly, and yearly testing per ST108:2023 and the VHA water contract/SOW. Completes performance qualification testing per the ST108:2023 and per the VHA contract/SOW. The contractor must report any outliers identified during testing within 24 hours of receiving laboratory results. Completes follow-up testing as ordered by engineering for out-of-range water parameters per the ST108:2023 and VHA water contract/SOW. The contractor shall provide VA end users with access to web-based reporting software for ongoing review of water testing data, historical trends, and compliance documentation. All reports must clearly highlight or delineate outliers and be designed to provide ease of reading, ensuring information is presented in a clear, organized, and actionable format. Contractor shall provide consultative services as needed, such as resolving abnormal water testing results, water system analysis, and mitigation of test results. AAMI ST108 UTILITY WATER, CRITICAL WATER, AND STEAM TESTING BY VENDOR: Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Utility Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Water Quality Measurement Units Type of Testing Routine Sample Site Utility Routine Sample Site Critical Utility Water Utility Water Critical Water Critical Water pH pH pH Meter or Colorimetric dipsticks Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 6.5-9.5 Monthly 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye UltrasonicX1 <500 Monthly <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <400 Monthly <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <150 Monthly <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) NA Decon sinks x3 Medivator Basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <500 Monthly <10 Monthly Endotoxin EU/mL LAL Test NA Decon sinks x3 Medivator Basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 NA NA <10 Monthly Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Water Quality Measurement Units Type of Testing Routine Sample Site Critical Critical Water Critical Water pH pH pH Meter or Colorimetric dipsticks Loop Supply Loop Return 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter (in line or measurement of a collected sample) Loop Supply Loop Return <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Loop Supply Loop Return <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Loop Supply Loop Return <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Loop Supply Loop Return <10 Monthly Endotoxin EU/mL LAL Test Loop Supply Loop Return <10 Monthly Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Water Quality Measurement Units Type of Testing PQ Sample Site Utility PQ Sample Site Critical PQ Sample Site Steam Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Water Quality Measurement Units Type of Testing PQ Sample Site Utility PQ Sample Site Critical PQ Sample Site Steam Utility Water Utility Water Critical Water Critical Water Steam Steam pH pH pH Meter or Colorimetric dipsticks Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 6.5-9.5 Quarterly 5.0-7.5 Monthly 5.0-9.2 Quarterly Conductivity uS/cm Conductivity Meter Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <500 Quarterly <10 Monthly <10 Quarterly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <400 Quarterly <8 Monthly <8 Quarterly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <150 Quarterly <1 Monthly <1 Quarterly Total Organic Carbon (TOC) mg/L (ppm) NA Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI NA NA NA <1.0 Quarterly NA NA Aluminum mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Chloride mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <250 Quarterly <1 Quarterly <1 Quarterly Copper mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Iron mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Manganese mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Nitrate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <10 Quarterly <1 Quarterly <1 Quarterly Phosphate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <5 Quarterly <1 Quarterly <1 Quarterly Silicate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <50 Quarterly <1 Quarterly <1 Quarterly Sulfate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <150 Quarterly <1 Quarterly <1 Quarterly Zinc mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Decon sinks x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filte

Read Full Official Summary

MODIFICATION STATEMENT OF WORK Sterile Processing Service ST-108 Testing Requirements Upgrade The contractor shall provide all the following for testing the water for/within SPS per the ANSI/AAMI ST108:2023 at the Marion, Fort Wayne, and Jackie Walorski VA sites as defined in this Statement of Work (SOW). WORK TO BE PERFORMED: Contractor shall provide all labor, materials, equipment, transportation, lodging, and supervision necessary to collect appropriate samples and deliver to a lab meeting the requirements for processing of AAMI ST108. Contractor shall calibrate the conductivity/resistivity meter monthly during their testing visit and provide a water analysis report. The contractor will be part of the multidisciplinary team that assists the water working group with resolving out-of-range water testing, in addition to: Serves as the subject matter expert on water testing per the ST108:2023 Serves as the subject matter expert on corrective actions to mitigate risks for out-of-range water testing parameters. Completes monthly, quarterly, and yearly testing per ST108:2023 and the VHA water contract/SOW. Completes performance qualification testing per the ST108:2023 and per the VHA contract/SOW. The contractor must report any outliers identified during testing within 24 hours of receiving laboratory results. Completes follow-up testing as ordered by engineering for out-of-range water parameters per the ST108:2023 and VHA water contract/SOW. The contractor shall provide VA end users with access to web-based reporting software for ongoing review of water testing data, historical trends, and compliance documentation. All reports must clearly highlight or delineate outliers and be designed to provide ease of reading, ensuring information is presented in a clear, organized, and actionable format. Contractor shall provide consultative services as needed, such as resolving abnormal water testing results, water system analysis, and mitigation of test results. AAMI ST108 UTILITY WATER, CRITICAL WATER, AND STEAM TESTING BY VENDOR: Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Fort Wayne Routine (monthly) POU Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Utility Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Water Quality Measurement Units Type of Testing Routine Sample Site Utility Routine Sample Site Critical Utility Water Utility Water Critical Water Critical Water pH pH pH Meter or Colorimetric dipsticks Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 6.5-9.5 Monthly 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye UltrasonicX1 <500 Monthly <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <400 Monthly <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Medivator Basin x4 Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <150 Monthly <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) NA Decon sinks x3 Medivator Basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 <500 Monthly <10 Monthly Endotoxin EU/mL LAL Test NA Decon sinks x3 Medivator Basin x4 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 NA NA <10 Monthly Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Fort Wayne Point of Generation Routine (monthly) Testing by Vendor Water Quality Measurement Units Type of Testing Routine Sample Site Critical Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Water Quality Measurement Units Type of Testing Routine Sample Site Critical Critical Water Critical Water pH pH pH Meter or Colorimetric dipsticks Loop Supply Loop Return 5.0-7.5 Monthly Conductivity uS/cm Conductivity Meter (in line or measurement of a collected sample) Loop Supply Loop Return <10 Monthly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Loop Supply Loop Return <8 Monthly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Loop Supply Loop Return <1 Monthly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Loop Supply Loop Return <10 Monthly Endotoxin EU/mL LAL Test Loop Supply Loop Return <10 Monthly Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Fort Wayne Performance Qualification Testing (quarterly) Testing by Vendor Water Quality Measurement Units Type of Testing PQ Sample Site Utility PQ Sample Site Critical PQ Sample Site Steam Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Minimum Frequency of Testing and Testing Range Water Quality Measurement Units Type of Testing PQ Sample Site Utility PQ Sample Site Critical PQ Sample Site Steam Utility Water Utility Water Critical Water Critical Water Steam Steam pH pH pH Meter or Colorimetric dipsticks Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 6.5-9.5 Quarterly 5.0-7.5 Monthly 5.0-9.2 Quarterly Conductivity uS/cm Conductivity Meter Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <500 Quarterly <10 Monthly <10 Quarterly Total Alkalinity mg CaCO3/L Colorimetric dipsticks or Alkalinity test kit Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <400 Quarterly <8 Monthly <8 Quarterly Total Hardness mg CaCO3/L Determination of ppm as CaCO3/L by colorimetric dipsticks, titration kit, or handheld meter Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <150 Quarterly <1 Monthly <1 Quarterly Total Organic Carbon (TOC) mg/L (ppm) NA Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI NA NA NA <1.0 Quarterly NA NA Aluminum mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Chloride mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <250 Quarterly <1 Quarterly <1 Quarterly Copper mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Iron mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Manganese mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Nitrate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <10 Quarterly <1 Quarterly <1 Quarterly Phosphate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <5 Quarterly <1 Quarterly <1 Quarterly Silicate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <50 Quarterly <1 Quarterly <1 Quarterly Sulfate mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <150 Quarterly <1 Quarterly <1 Quarterly Zinc mg/L Decon sinks x4 Medivator Basin x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filter Medivator 1 Supply Medivator 2 Supply Decon sinks x3 Washer x1 Ultrasonic x1 Eye Ultrasonic X1 Loop Supply Loop Return After RO After DI Sterilizer x2 <0.1 Quarterly <0.1 Quarterly <0.1 Quarterly Bacteria CFU/mL Heterotrophic Plate Count (HPC) Decon sinks x4 Washer x2 Ultrasonic x2 Eye Ultrasonic X2 City Water Water Softener Utility DI After Carbon Filte

Official SAM.gov Contract Opportunities file extract excerpt for this notice. The stored text is the first 12,000 characters of the normalized official source, not the complete source body. CaptureIQ does not generate or rewrite this text.

Related Federal Opportunities

Why this matters

  • This notice is a presolicitation.
  • The listed response deadline is Nov 4, 2026.
  • 4 related opportunities share this NAICS.

Related federal terms

  • RFI — Request for Information
  • SDVOSB — Service-Disabled Veteran-Owned Small Business
  • NAICS — North American Industry Classification System

Market context

4 Related OpportunitiesMatching opportunities on RFPCapture

Related intelligence

Research and capture tools

This notice carries an explicit small-business set-aside designation.

← All federal opportunities · Federal Opportunity Research

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.