H335--Amendment One| Elevator Third-Party Inspection and Testing Services BK & SA

Veterans Affairs, Department Of.242-network Contract Office 02 (36c242)Combined Synopsis/SolicitationSolicitation 36C24226Q0845

Response deadline

Fri, Oct 16, 2026, 3:30 PM EDT

Product Service Code

PSC H335
Analyze This Opportunity in CaptureIQ

Compare your company's capabilities against this federal opportunity using CaptureIQ.

Ready to Pursue This Opportunity?

Qualify the fit, analyze competitors, identify teaming partners, and generate review-ready materials — all in CaptureIQ.

  • Federal capture workflow
  • Competitor & teaming intelligence
  • Proposal preparation

Opportunity details

NAICS
541350
Notice type
Combined Synopsis/Solicitation
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Original posted
October 8, 2026
Last updated
October 18, 2026
Notice ID
5b2a9df613aa42c296d41700fd0fd78c

Summary

Elevator Third-Party Inspection and Testing Services for the Brooklyn VA Medical Center and St. Albans VA Medical Center Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01. This solicitation is set aside for SDVOSBs. The associated North American Industrial Classification System (NAICS) code for this procurement is 541350- Building Inspection Services, with a small business size standard of $11.5 million. The FSC/PSC is H335. The Veterans Health Administration of Brooklyn and VA St. Albans CLC has a requirement for a Five-Year Safety Test (Category 5) elevator inspection services and an annual safety test of elevators and dumbwaiters inspection services (Category 1). All interested companies shall provide quotations for the following: Supplies/Services Line Item Description Quantity Unit of Measure Unit Price Total Price BASE PERIOD- 09/07/2026 09/06/2027 0001 VA Medical Center Brooklyn Five-Year Load Test- Elevator 23 EA 0002 VA St. Albans Five-Year Load Test- Elevator 9 EA 0003 VA Medical Center Brooklyn Five-Year Load Test-Dumbwaiters 4 EA 0004 VA Medical Center Brooklyn Semi-Annual Elevator Inspection (23 elevators) 1 JB 0005 VA St. Albans Semi-Annual Elevator Inspection (9 elevators) 1 JB 0006 VA Medical Center Brooklyn Annual Dumbwaiters Inspection 4 EA 0007 VA Medical Center Brooklyn Semi-Annual Dumbwaiters Inspection (4 dumbwaiters) 1 JB 0008 Provide Parts/Material 1 LT Refer to FAR 52.212-1 0009 Corrective Action Re-Inspection (elevator/dumbwaiter re-inspection) 1 HR OPTION PERIOD ONE - 09/07/2027 09/06/2028 1001 VA Medical Center Brooklyn Annual Elevator Inspection 23 EA 1002 VA St. Albans Annual Elevator Inspection 9 EA 1003 VA Medical Center Brooklyn Semi-Annual Elevator Inspection (23 elevators) 1 JB 1004 VA St. Albans Semi-Annual Elevator Inspection (9 elevators) 1 JB 1005 VA Medical Center Brooklyn Annual Dumbwaiters Inspection 4 EA 1006 VA Medical Center Brooklyn Semi-Annual Dumbwaiters Inspection (4 dumbwaiters) 1 JB 1007 Provide Parts/Material 1 LT Refer to FAR 52.212-1 1008 Corrective Action Re-Inspection (elevator/dumbwaiter re-inspection) 1 HR OPTION PERIOD TWO- 09/07/2028 09/06/2029 2001 VA Medical Center Brooklyn Annual Elevator Inspection 23 EA 2002 VA St. Albans Annual Elevator Inspection 9 EA 2003 VA Medical Center Brooklyn Semi-Annual Elevator Inspection (23 elevators) 1 JB 2004 VA St. Albans Semi-Annual Elevator Inspection (9 elevators) 1 JB 2005 VA Medical Center Brooklyn Annual Dumbwaiters Inspection 4 EA 2006 VA Medical Center Brooklyn Semi-Annual Dumbwaiters Inspection (4 dumbwaiters) 1 JB 2007 Provide Parts/Material 1 LT Refer to FAR 52.212-1 2008 Corrective Action Re-Inspection (elevator/dumbwaiter re-inspection) 1 HR OPTION PERIOD THREE - 09/07/2029 09/06/2030 3001 VA Medical Center Brooklyn Annual Elevator Inspection 23 EA 3002 VA St. Albans Annual Elevator Inspection 9 EA 3003 VA Medical Center Brooklyn Semi-Annual Elevator Inspection (23 elevators) 1 JB 3004 VA St. Albans Semi-Annual Elevator Inspection (9 elevators) 1 JB 3005 VA Medical Center Brooklyn Annual Dumbwaiters Inspection 4 EA 3006 VA Medical Center Brooklyn Semi-Annual Dumbwaiters Inspection (4 dumbwaiters) 1 JB 3007 Provide Parts/Material 1 LT Refer to FAR 52.212-1 3008 Corrective Action Re-Inspection (elevator/dumbwaiter re-inspection) 1 HR OPTION PERIOD FOUR - 09/07/2030 09/06/2031 4001 VA Medical Center Brooklyn Annual Elevator Inspection 23 EA 4002 VA St. Albans Annual Elevator Inspection 9 EA 4003 VA Medical Center Brooklyn Semi-Annual Elevator Inspection (23 elevators) 1 JB 4004 VA St. Albans Semi-Annual Elevator Inspection (9 elevators) 1 JB 4005 VA Medical Center Brooklyn Annual Dumbwaiters Inspection 4 EA 4006 VA Medical Center Brooklyn Semi-Annual Dumbwaiters Inspection (4 dumbwaiters) 1 JB 4007 Provide Parts/Material 1 LT Refer to FAR 52.212-1 4008 Corrective Action Re-Inspection (elevator/dumbwaiter re-inspection) 1 HR STATEMENT OF WORK (SOW) SCOPE OF WORK: The Contractor shall provide elevator inspection services under a 12-month base contract period, including four option years. Services shall include the performance of a Five-Year Safety Test (Category 5) inspection as well as annual and semiannual Safety Tests inspections (Category 1) for elevators and dumbwaiters. All services shall be performed at the following addresses- Address: Brooklyn VA Medical Center 800 Poly Place Brooklyn, NY 11209-7104 St. Albans VA Medical Center 179-00 Linden Boulevard Queens, NY 11424-1468 OBJECTIVE: The Contractor shall inspect five-year safety tests when applicable and annual and semiannual safety test of elevators and dumbwaiters in accordance with all requirements set in the base year and all four option periods. PERFORMANCE PERIOD: The government requires a 12-month base contract period, including four option years Base: 09/07/2026 09/06/2027 Option 1: 09/07/2027 09/06/2028 Option 2: 09/07/2028 09/06/2029 Option 3: 09/07/2029 09/06/2030 Option 4: 09/07/2030 09/06/2031 ANNUAL AND SEMIANNUAL SAFETY TEST: An annual and semiannual safety test will be performed on elevators/dumbwaiters. Safeties shall be subjected to an annual and semiannual running test as indicated per OSHA 1917.116 / ASME A17.1. The slowest operating speed, at no load test required for annual test as indicated as per OSHA 1917.116 / ASME A17.1. The Maintenance Contractor (separate vendor providing testing services) is required to furnish the tools and labor to perform the annual and semiannual no-load tests. Phase-1 Lobby Key Switch and Phase-2 Service check should be accomplished during the annual and semiannual safety check. The Maintenance Contractor shall attach tags after testing as required by ASME A17.1 and A17.2. The Maintenance Contractor shall not take out more than one elevator at a time and coordinate with facility for not impacting patient care or operations of the facility. The Maintenance Contractor provides all required equipment (inspectors do not supply, handle, or move weights). Note: The details above describe the procedures carried out by the Maintenance Contractor, but the requirements related to inspecting the Annual and Semiannual Safety Tests inspection. ANNUAL AND SEMIANNUAL SAFETY TEST INSPECTIONS: Inspection to be performed January or within 30 days of award. Semiannual to be performed in July or six months after the annual inspection. The Contractor will witness and certify the inspection. Inspections are to be made in accordance with the Safety Code for Elevators, ASME A17.1 latest edition. Inspections and documentation shall be in accordance with American Society of Mechanical Engineers A17.1, A17.2, A17.3, A17.4 most recent edition and addenda standard. The COR shall accompany the contractor as an observer during the entire time of each inspection. The Contractor Inspectors do not perform maintenance or tests; they only witness, certify, and report FIVE YEAR SAFETY TEST: A five-year safety test will be performed on elevators and dumbwaiters listed during the base year of the contract within 30 days of award. Safeties shall be subjected to the ASME testing standards for car and counterweights, governors and oil buffers as per OSHA 1917.116 / ASME A17.1. 6167, Report of Test of Elevator Governor and Safety Device which is included in this contract. Test leveling zone and leveling speeds with contract load. Test the door pressure and kinetic energy. Test governors pull through tension. Record the following but not limiting to: capacity, speed empty up and down, speed loaded up and down, safety jaw tripping speed, over-speed governor tripping speed, safety slide on the rails, governor pull through, governor plate speed, car level after test, buffer return time, complete firefighters service check as applicable, and safety rope pull out as applicable. A five-year load test is required. Testing requires test weights. No fifty-five-gallon drums filled with water or 1000 lb weights will be accepted for use on load tests. The Maintenance Contractor (separate vendor providing testing services) is required to furnish weights, tools, and labor to perform the five-year full load test. All work is to be performed in accordance with 5-year inspection test requirements, ASME A17.1 latest edition. During the performance of the five (5) year test requirements, adjacent elevators shall be removed from service in the interest of safety in accordance with ASME A17.2.1. The Maintenance Contractor shall not take out more than one elevator at a time and coordinate with facility for not impacting patient care or operations of the facility. Elevators are to be run at slow speed. The Maintenance Contractor provides all required equipment (inspectors do not supply, handle, or move weights). Note: The details above describe the procedures carried out by the Maintenance Contractor, but the requirements relate to inspecting the Five-Year Safety Test inspection. FIVE YEAR SAFETY TEST INSPECTION: Perform all inspections and tests in strict accordance with ANSI/ASME A17.1 plus A17.2. List code violations observed during tests. The Contractor will witness and certify the inspection. Inspections and documentation shall be in accordance with American Society of Mechanical Engineers A17.1, A17.2, A17.3, A17.4 most recent edition and addenda standard. The COR shall accompany the contractor as an observer during the entire time of each inspection. The Contractor Inspectors do not perform maintenance or tests; they only witness, certify, and report RETESTING AND RE-INSPECTION OF CORRECTIVE ACTIONS: If an elevator or dumbwaiter fails any inspection under this contract, the contractor shall document all cited deficiencies in the inspection report. Once the maintenance contractor completes corrective action, the inspector shall re-inspect the affected unit to verify the deficiencies have been corrected Re-inspections shall be invoiced under the Corrective Action Re-Inspection line item. Re-inspections needed due to the Contractor's own error shall be performed at no additional cost. REPORTS: The Contractor shall submit report(s) upon completion of the inspection. For all items on such forms which are not applicable, the notation "NA" (not applicable) shall be made. Reports will be prepared and submitted- two (2) hard copies and two (2) electronic copies, no later than 15 working days following the inspection to the VA Medical Center Attention: Engineering Service (138), COR as noted at time of award. SCHEDULE OF INSPECTIONS AND WORK HOURS: The annual safety test shall be made during the months indicated on the list of elevators/dumbwaiters for the VA Medical Center. Work required in the performance of this contract shall be performed during the VA Medical Center's regular administrative working hours, which are 8:00 a.m. to 4:30 p.m., Monday through Friday, excluding Federal holidays. Federal Holidays which are observed by the federal government are annotated below New Year s Day Martin Luther King s Birthday President s Day Memorial Day Juneteenth Independence Day Labor Day Columbus Day Veterans Day Thanksgiving Day Christmas Day Any other days specifically by the President of the United States to be a national holiday Both the Contractor and Maintenance Contractor shall notify the COR or designee, at least 2 weeks in advance to coordinate the time and date of the i

Read Full Official Summary

Elevator Third-Party Inspection and Testing Services for the Brooklyn VA Medical Center and St. Albans VA Medical Center Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01. This solicitation is set aside for SDVOSBs. The associated North American Industrial Classification System (NAICS) code for this procurement is 541350- Building Inspection Services, with a small business size standard of $11.5 million. The FSC/PSC is H335. The Veterans Health Administration of Brooklyn and VA St. Albans CLC has a requirement for a Five-Year Safety Test (Category 5) elevator inspection services and an annual safety test of elevators and dumbwaiters inspection services (Category 1). All interested companies shall provide quotations for the following: Supplies/Services Line Item Description Quantity Unit of Measure Unit Price Total Price BASE PERIOD- 09/07/2026 09/06/2027 0001 VA Medical Center Brooklyn Five-Year Load Test- Elevator 23 EA 0002 VA St. Albans Five-Year Load Test- Elevator 9 EA 0003 VA Medical Center Brooklyn Five-Year Load Test-Dumbwaiters 4 EA 0004 VA Medical Center Brooklyn Semi-Annual Elevator Inspection (23 elevators) 1 JB 0005 VA St. Albans Semi-Annual Elevator Inspection (9 elevators) 1 JB 0006 VA Medical Center Brooklyn Annual Dumbwaiters Inspection 4 EA 0007 VA Medical Center Brooklyn Semi-Annual Dumbwaiters Inspection (4 dumbwaiters) 1 JB 0008 Provide Parts/Material 1 LT Refer to FAR 52.212-1 0009 Corrective Action Re-Inspection (elevator/dumbwaiter re-inspection) 1 HR OPTION PERIOD ONE - 09/07/2027 09/06/2028 1001 VA Medical Center Brooklyn Annual Elevator Inspection 23 EA 1002 VA St. Albans Annual Elevator Inspection 9 EA 1003 VA Medical Center Brooklyn Semi-Annual Elevator Inspection (23 elevators) 1 JB 1004 VA St. Albans Semi-Annual Elevator Inspection (9 elevators) 1 JB 1005 VA Medical Center Brooklyn Annual Dumbwaiters Inspection 4 EA 1006 VA Medical Center Brooklyn Semi-Annual Dumbwaiters Inspection (4 dumbwaiters) 1 JB 1007 Provide Parts/Material 1 LT Refer to FAR 52.212-1 1008 Corrective Action Re-Inspection (elevator/dumbwaiter re-inspection) 1 HR OPTION PERIOD TWO- 09/07/2028 09/06/2029 2001 VA Medical Center Brooklyn Annual Elevator Inspection 23 EA 2002 VA St. Albans Annual Elevator Inspection 9 EA 2003 VA Medical Center Brooklyn Semi-Annual Elevator Inspection (23 elevators) 1 JB 2004 VA St. Albans Semi-Annual Elevator Inspection (9 elevators) 1 JB 2005 VA Medical Center Brooklyn Annual Dumbwaiters Inspection 4 EA 2006 VA Medical Center Brooklyn Semi-Annual Dumbwaiters Inspection (4 dumbwaiters) 1 JB 2007 Provide Parts/Material 1 LT Refer to FAR 52.212-1 2008 Corrective Action Re-Inspection (elevator/dumbwaiter re-inspection) 1 HR OPTION PERIOD THREE - 09/07/2029 09/06/2030 3001 VA Medical Center Brooklyn Annual Elevator Inspection 23 EA 3002 VA St. Albans Annual Elevator Inspection 9 EA 3003 VA Medical Center Brooklyn Semi-Annual Elevator Inspection (23 elevators) 1 JB 3004 VA St. Albans Semi-Annual Elevator Inspection (9 elevators) 1 JB 3005 VA Medical Center Brooklyn Annual Dumbwaiters Inspection 4 EA 3006 VA Medical Center Brooklyn Semi-Annual Dumbwaiters Inspection (4 dumbwaiters) 1 JB 3007 Provide Parts/Material 1 LT Refer to FAR 52.212-1 3008 Corrective Action Re-Inspection (elevator/dumbwaiter re-inspection) 1 HR OPTION PERIOD FOUR - 09/07/2030 09/06/2031 4001 VA Medical Center Brooklyn Annual Elevator Inspection 23 EA 4002 VA St. Albans Annual Elevator Inspection 9 EA 4003 VA Medical Center Brooklyn Semi-Annual Elevator Inspection (23 elevators) 1 JB 4004 VA St. Albans Semi-Annual Elevator Inspection (9 elevators) 1 JB 4005 VA Medical Center Brooklyn Annual Dumbwaiters Inspection 4 EA 4006 VA Medical Center Brooklyn Semi-Annual Dumbwaiters Inspection (4 dumbwaiters) 1 JB 4007 Provide Parts/Material 1 LT Refer to FAR 52.212-1 4008 Corrective Action Re-Inspection (elevator/dumbwaiter re-inspection) 1 HR STATEMENT OF WORK (SOW) SCOPE OF WORK: The Contractor shall provide elevator inspection services under a 12-month base contract period, including four option years. Services shall include the performance of a Five-Year Safety Test (Category 5) inspection as well as annual and semiannual Safety Tests inspections (Category 1) for elevators and dumbwaiters. All services shall be performed at the following addresses- Address: Brooklyn VA Medical Center 800 Poly Place Brooklyn, NY 11209-7104 St. Albans VA Medical Center 179-00 Linden Boulevard Queens, NY 11424-1468 OBJECTIVE: The Contractor shall inspect five-year safety tests when applicable and annual and semiannual safety test of elevators and dumbwaiters in accordance with all requirements set in the base year and all four option periods. PERFORMANCE PERIOD: The government requires a 12-month base contract period, including four option years Base: 09/07/2026 09/06/2027 Option 1: 09/07/2027 09/06/2028 Option 2: 09/07/2028 09/06/2029 Option 3: 09/07/2029 09/06/2030 Option 4: 09/07/2030 09/06/2031 ANNUAL AND SEMIANNUAL SAFETY TEST: An annual and semiannual safety test will be performed on elevators/dumbwaiters. Safeties shall be subjected to an annual and semiannual running test as indicated per OSHA 1917.116 / ASME A17.1. The slowest operating speed, at no load test required for annual test as indicated as per OSHA 1917.116 / ASME A17.1. The Maintenance Contractor (separate vendor providing testing services) is required to furnish the tools and labor to perform the annual and semiannual no-load tests. Phase-1 Lobby Key Switch and Phase-2 Service check should be accomplished during the annual and semiannual safety check. The Maintenance Contractor shall attach tags after testing as required by ASME A17.1 and A17.2. The Maintenance Contractor shall not take out more than one elevator at a time and coordinate with facility for not impacting patient care or operations of the facility. The Maintenance Contractor provides all required equipment (inspectors do not supply, handle, or move weights). Note: The details above describe the procedures carried out by the Maintenance Contractor, but the requirements related to inspecting the Annual and Semiannual Safety Tests inspection. ANNUAL AND SEMIANNUAL SAFETY TEST INSPECTIONS: Inspection to be performed January or within 30 days of award. Semiannual to be performed in July or six months after the annual inspection. The Contractor will witness and certify the inspection. Inspections are to be made in accordance with the Safety Code for Elevators, ASME A17.1 latest edition. Inspections and documentation shall be in accordance with American Society of Mechanical Engineers A17.1, A17.2, A17.3, A17.4 most recent edition and addenda standard. The COR shall accompany the contractor as an observer during the entire time of each inspection. The Contractor Inspectors do not perform maintenance or tests; they only witness, certify, and report FIVE YEAR SAFETY TEST: A five-year safety test will be performed on elevators and dumbwaiters listed during the base year of the contract within 30 days of award. Safeties shall be subjected to the ASME testing standards for car and counterweights, governors and oil buffers as per OSHA 1917.116 / ASME A17.1. 6167, Report of Test of Elevator Governor and Safety Device which is included in this contract. Test leveling zone and leveling speeds with contract load. Test the door pressure and kinetic energy. Test governors pull through tension. Record the following but not limiting to: capacity, speed empty up and down, speed loaded up and down, safety jaw tripping speed, over-speed governor tripping speed, safety slide on the rails, governor pull through, governor plate speed, car level after test, buffer return time, complete firefighters service check as applicable, and safety rope pull out as applicable. A five-year load test is required. Testing requires test weights. No fifty-five-gallon drums filled with water or 1000 lb weights will be accepted for use on load tests. The Maintenance Contractor (separate vendor providing testing services) is required to furnish weights, tools, and labor to perform the five-year full load test. All work is to be performed in accordance with 5-year inspection test requirements, ASME A17.1 latest edition. During the performance of the five (5) year test requirements, adjacent elevators shall be removed from service in the interest of safety in accordance with ASME A17.2.1. The Maintenance Contractor shall not take out more than one elevator at a time and coordinate with facility for not impacting patient care or operations of the facility. Elevators are to be run at slow speed. The Maintenance Contractor provides all required equipment (inspectors do not supply, handle, or move weights). Note: The details above describe the procedures carried out by the Maintenance Contractor, but the requirements relate to inspecting the Five-Year Safety Test inspection. FIVE YEAR SAFETY TEST INSPECTION: Perform all inspections and tests in strict accordance with ANSI/ASME A17.1 plus A17.2. List code violations observed during tests. The Contractor will witness and certify the inspection. Inspections and documentation shall be in accordance with American Society of Mechanical Engineers A17.1, A17.2, A17.3, A17.4 most recent edition and addenda standard. The COR shall accompany the contractor as an observer during the entire time of each inspection. The Contractor Inspectors do not perform maintenance or tests; they only witness, certify, and report RETESTING AND RE-INSPECTION OF CORRECTIVE ACTIONS: If an elevator or dumbwaiter fails any inspection under this contract, the contractor shall document all cited deficiencies in the inspection report. Once the maintenance contractor completes corrective action, the inspector shall re-inspect the affected unit to verify the deficiencies have been corrected Re-inspections shall be invoiced under the Corrective Action Re-Inspection line item. Re-inspections needed due to the Contractor's own error shall be performed at no additional cost. REPORTS: The Contractor shall submit report(s) upon completion of the inspection. For all items on such forms which are not applicable, the notation "NA" (not applicable) shall be made. Reports will be prepared and submitted- two (2) hard copies and two (2) electronic copies, no later than 15 working days following the inspection to the VA Medical Center Attention: Engineering Service (138), COR as noted at time of award. SCHEDULE OF INSPECTIONS AND WORK HOURS: The annual safety test shall be made during the months indicated on the list of elevators/dumbwaiters for the VA Medical Center. Work required in the performance of this contract shall be performed during the VA Medical Center's regular administrative working hours, which are 8:00 a.m. to 4:30 p.m., Monday through Friday, excluding Federal holidays. Federal Holidays which are observed by the federal government are annotated below New Year s Day Martin Luther King s Birthday President s Day Memorial Day Juneteenth Independence Day Labor Day Columbus Day Veterans Day Thanksgiving Day Christmas Day Any other days specifically by the President of the United States to be a national holiday Both the Contractor and Maintenance Contractor shall notify the COR or designee, at least 2 weeks in advance to coordinate the time and date of the i

Official SAM.gov Contract Opportunities file extract excerpt for this notice. The stored text is the first 12,000 characters of the normalized official source, not the complete source body. CaptureIQ does not generate or rewrite this text.

Related Federal Opportunities

Why this matters

  • This notice is a combined synopsis/solicitation.
  • The listed response deadline is Oct 16, 2026.
  • 4 related opportunities share this NAICS.

Related federal terms

  • SDVOSB — Service-Disabled Veteran-Owned Small Business
  • NAICS — North American Industry Classification System
  • PSC — Product Service Code

Market context

4 Related OpportunitiesMatching opportunities on RFPCapture

Related intelligence

Research and capture tools

This notice carries an explicit small-business set-aside designation.

← All federal opportunities · Federal Opportunity Research

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.