SAM.gov listing

H946--Sterile Processing Water Quality Chillicothe VA Medical Center

Veterans Affairs, Department Of.250-network Contract Office 10 (36c250)Sources SoughtSolicitation 36C25026Q0430

Response deadline

Thu, Sep 3, 2026, 1:00 PM EDT

Product Service Code

PSC H946

NAICS code

NAICS 221310
Analyze This Opportunity in CaptureIQ

Compare your company's capabilities against this federal opportunity using CaptureIQ.

Ready to Pursue This Opportunity?

Qualify the fit, analyze competitors, identify teaming partners, and generate review-ready materials — all in CaptureIQ.

  • Federal capture workflow
  • Competitor & teaming intelligence
  • Proposal preparation

Opportunity details

NAICS
221310
Notice type
Sources Sought
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Original posted
August 27, 2026
Last updated
October 18, 2026
Notice ID
7c8c43f614ec44fda70239c53e816f95

Summary

Delivery Schedule: The coordinating service for this initiative is CVAMC Engineering CORS. All services will be approved, coordinated, and scheduled with the Engineering COR at contract award. All items will be delivered, and first maintenance scheduled within 30 days of contract award. Monthly service visits to be scheduled within the first week of each month. Quarterly PM service visits to be scheduled within the first week of each quarter. Service reports and water quality analysis reports should be delivered via email to the VAMC Engineering COR within five (5) business days of visit, or in the case of longer-duration tests, within three (3) days of receiving results from outside lab testing. All work must be performed during normal working shifts, 8:00 a.m. to 4:30 p.m., Monday through Friday, excluding Federal holidays, however some tasks may need to be performed outside normal working shifts and days. The vendor will schedule & coordinate all work with Engineering COR and Chief SPS. The contractor personnel shall sign into (and out of) the facility and obtain a Vendor s ID Badge upon every visit at Engineering, Building 21. The contractor shall then check in and check out and report to the Engineering COR in Building 21 and return the Vendor s ID Badge to Engineering, Building 21. Period of Performance: Base Year + 4 Option Years. ========================================================================= Evaluation Factors - Chillicothe VAMC Sterile Processing Water Quality ===================================================================================== 1.Maintenance a. Experience and materials for service i. CPVC Piping and Fittings ii. Polypropylene Thermal Fusion Piping and Fittings iii. 5844C DI Tanks iv. Prefilter 5-micron melt blown cartridge - post DI 675100 v. Final 0.2-micron absolute polyester pleated cartridge 675145 vi. Carbon block 10-micron prefilter 2.5 x 20 cartridge 675113 vii .RO Membranes 4 x 26" XLE4021 viii. UV Lamp GL39PP (UV Lamp - 1 Year Life Change Sept) - UV module part number UVA-12C (Hydronix) b. Emergency Response Capability i. Declaration of response within 1 business day (as based on federal calendar) ii. Nearest Service Location 1.Locations within 100 miles will receive priority 2.Locations within 200 miles will receive preference 2.Water Quality Analysis a. Laboratory Qualifications i. ISO/IEC 17025 ii. Ohio Environmental Protection Agency (Not applicable to Endotoxins ANSI/AAMI ST72/USP 85) iii. Equivalent certification to be determined by facility review. b. Sampling Procedures i. Submit company policy/procedures. ii. Sampler Resume 1.Shall have a minimum of 5 years of experience. 2.Experience with biological sampling to include Heterotopic Plate Count and Endotoxin iii. Virtual interview with sampler will be requested c. Transportation and Storage Procedures i. Submit company policy/procedures ii. Maximum transit time not to exceed 8 hours to lab intake. d. Reporting i. Example Report Reviewed for contents and organization 1. Shall include: a. Biological analysis results b. Chemical analysis results c .AAMI ST108 Thresholds d. Identify Water* Quality Classification i. Utility Water ii. Critical Water iii. AER iv. Steam* - Steam Condensate e. Remediation recommendations 2. An actual report is permitted, however facility identifying information shall be redacted. 3. Report shall be watermarked or stamped on all pages with Example 3. Familiarity with AAMI ST108, Bacteriological Water Quality Management, and Water Treatment Technologies a. Specialist Resume(s) b. Virtual interview with specialist(s) will be requested. c. Specialist(s) may be an individual or multiple individuals. d. Bacteriological Water Quality Management i. Disinfection methods 1.Manual Administration a. Liquid disinfectants b. Dissolved oxidizing gas c. Concentration and Contact Time Requirements 2.Automated/Energized Systems a. Ultraviolet b. Metered liquid disinfection systems c. Dissolved oxidizing gas ii. Material/Chemical Compatibility iii. Safety Requirements iv. Costs 1. Initial 2. Operation/Maintenance e. Water Treatment Technology Familiarity i. Shall include: 1. Reverse Osmosis 2. Filtration Technologies a. To include Carbon Filtration 3. Ion Exchange Technologies 4. Water Softeners ii. Material/Chemical Compatibility iii. Sizing of Technology iv. Operations and Maintenance Requirements v. Safety Requirements vi. Costs 1.Initial 2.Operation/Maintenance

Read Full Official Summary

Delivery Schedule: The coordinating service for this initiative is CVAMC Engineering CORS. All services will be approved, coordinated, and scheduled with the Engineering COR at contract award. All items will be delivered, and first maintenance scheduled within 30 days of contract award. Monthly service visits to be scheduled within the first week of each month. Quarterly PM service visits to be scheduled within the first week of each quarter. Service reports and water quality analysis reports should be delivered via email to the VAMC Engineering COR within five (5) business days of visit, or in the case of longer-duration tests, within three (3) days of receiving results from outside lab testing. All work must be performed during normal working shifts, 8:00 a.m. to 4:30 p.m., Monday through Friday, excluding Federal holidays, however some tasks may need to be performed outside normal working shifts and days. The vendor will schedule & coordinate all work with Engineering COR and Chief SPS. The contractor personnel shall sign into (and out of) the facility and obtain a Vendor s ID Badge upon every visit at Engineering, Building 21. The contractor shall then check in and check out and report to the Engineering COR in Building 21 and return the Vendor s ID Badge to Engineering, Building 21. Period of Performance: Base Year + 4 Option Years. ========================================================================= Evaluation Factors - Chillicothe VAMC Sterile Processing Water Quality ===================================================================================== 1.Maintenance a. Experience and materials for service i. CPVC Piping and Fittings ii. Polypropylene Thermal Fusion Piping and Fittings iii. 5844C DI Tanks iv. Prefilter 5-micron melt blown cartridge - post DI 675100 v. Final 0.2-micron absolute polyester pleated cartridge 675145 vi. Carbon block 10-micron prefilter 2.5 x 20 cartridge 675113 vii .RO Membranes 4 x 26" XLE4021 viii. UV Lamp GL39PP (UV Lamp - 1 Year Life Change Sept) - UV module part number UVA-12C (Hydronix) b. Emergency Response Capability i. Declaration of response within 1 business day (as based on federal calendar) ii. Nearest Service Location 1.Locations within 100 miles will receive priority 2.Locations within 200 miles will receive preference 2.Water Quality Analysis a. Laboratory Qualifications i. ISO/IEC 17025 ii. Ohio Environmental Protection Agency (Not applicable to Endotoxins ANSI/AAMI ST72/USP 85) iii. Equivalent certification to be determined by facility review. b. Sampling Procedures i. Submit company policy/procedures. ii. Sampler Resume 1.Shall have a minimum of 5 years of experience. 2.Experience with biological sampling to include Heterotopic Plate Count and Endotoxin iii. Virtual interview with sampler will be requested c. Transportation and Storage Procedures i. Submit company policy/procedures ii. Maximum transit time not to exceed 8 hours to lab intake. d. Reporting i. Example Report Reviewed for contents and organization 1. Shall include: a. Biological analysis results b. Chemical analysis results c .AAMI ST108 Thresholds d. Identify Water* Quality Classification i. Utility Water ii. Critical Water iii. AER iv. Steam* - Steam Condensate e. Remediation recommendations 2. An actual report is permitted, however facility identifying information shall be redacted. 3. Report shall be watermarked or stamped on all pages with Example 3. Familiarity with AAMI ST108, Bacteriological Water Quality Management, and Water Treatment Technologies a. Specialist Resume(s) b. Virtual interview with specialist(s) will be requested. c. Specialist(s) may be an individual or multiple individuals. d. Bacteriological Water Quality Management i. Disinfection methods 1.Manual Administration a. Liquid disinfectants b. Dissolved oxidizing gas c. Concentration and Contact Time Requirements 2.Automated/Energized Systems a. Ultraviolet b. Metered liquid disinfection systems c. Dissolved oxidizing gas ii. Material/Chemical Compatibility iii. Safety Requirements iv. Costs 1. Initial 2. Operation/Maintenance e. Water Treatment Technology Familiarity i. Shall include: 1. Reverse Osmosis 2. Filtration Technologies a. To include Carbon Filtration 3. Ion Exchange Technologies 4. Water Softeners ii. Material/Chemical Compatibility iii. Sizing of Technology iv. Operations and Maintenance Requirements v. Safety Requirements vi. Costs 1.Initial 2.Operation/Maintenance

Official SAM.gov Contract Opportunities file extract description for this notice. CaptureIQ does not generate or rewrite this text.

Related Federal Opportunities

Why this matters

  • This notice is a sources sought.
  • The listed response deadline is Sep 3, 2026.
  • 4 related opportunities share this NAICS.

Related federal terms

  • RFI — Request for Information
  • SDVOSB — Service-Disabled Veteran-Owned Small Business
  • NAICS — North American Industry Classification System

Market context

4 Related OpportunitiesMatching opportunities on RFPCapture

Related intelligence

Research and capture tools

This notice carries an explicit small-business set-aside designation.

← All federal opportunities · Federal Opportunity Research

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.