Response deadline
Thu, Jul 9, 2026, 10:00 AM EDTZ2DA--542-26-109 | Replace Flat Roof Building 57 | NCO 4 Construction East (VA-26-00053279)
Compare your company's capabilities against this federal opportunity using CaptureIQ.
Opportunity details
- NAICS
- 236220
- Notice type
- Presolicitation
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Original posted
- May 19, 2026
- Last updated
- October 18, 2026
- Notice ID
- 4742494cec2c4b35998ac3ffe1760587
Summary
Project Title: Replace Flat Roof Building 57 Project Number: 542 26 109 Description: The Department of Veterans Affairs, Coatesville VA Medical Center (VAMC), intends to issue an Invitation for Bid (IFB) for Project 542 26 109, Replace Flat Roof Building 57. The work includes the full replacement of the EPDM flat roof systems on Building 57, including the southern basement entrance/exit roof. Scope includes removal and replacement of the EPDM membrane, insulation, cants, flashing, and associated roof components; correcting roof pitch to designated roof drains; repairing concrete decking; removing abandoned rooftop equipment; replacing the existing exhaust fan and damaged exhaust hood; and installing new lightning protection for affected equipment. All work shall comply with the VA Technical Information Library (TIL), Master Construction Specifications, OSHA construction safety standards, manufacturer installation requirements, and applicable federal, state, and local regulations. The period of performance is 90 days from the Notice to Proceed.
Read Full Official Summary
Project Title: Replace Flat Roof Building 57 Project Number: 542 26 109 Description: The Department of Veterans Affairs, Coatesville VA Medical Center (VAMC), intends to issue an Invitation for Bid (IFB) for Project 542 26 109, Replace Flat Roof Building 57. The work includes the full replacement of the EPDM flat roof systems on Building 57, including the southern basement entrance/exit roof. Scope includes removal and replacement of the EPDM membrane, insulation, cants, flashing, and associated roof components; correcting roof pitch to designated roof drains; repairing concrete decking; removing abandoned rooftop equipment; replacing the existing exhaust fan and damaged exhaust hood; and installing new lightning protection for affected equipment. All work shall comply with the VA Technical Information Library (TIL), Master Construction Specifications, OSHA construction safety standards, manufacturer installation requirements, and applicable federal, state, and local regulations. The period of performance is 90 days from the Notice to Proceed.
Related Federal Opportunities
Why this matters
- This notice is a presolicitation.
- The listed response deadline is Jul 9, 2026.
- 4 related opportunities share this NAICS.
Related federal terms
Market context
4 Related OpportunitiesMatching opportunities on RFPCapture