Explore This Research Award in CaptureIQ
Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.
Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- BARRON ASSOCIATES, INC.
- Proposal award date
- 2018-09-01
- Contract end date
- 2019-08-31
- UEI
- C8FUKQKC9JB4
- Solicitation number
- PA17-302
- Topic code
- R
Research abstract
Summary Abstract
Indirect calorimetry is based on measurement of the exchange of respiratory gasesAll aerobic energy releasing reactions in the body use oxygenoxygen consumptionV Ois proportional to energy expenditureEEResearchgrade indirect calorimetry systems measure V Ocarbon dioxide productionV COand minute ventilationV Ebreath by breath and then average results over multiple breaths to obtain accurate measures of cardiorespiratory
functionThe maximum attainable VOi eVO maxis the gold standard for assessing cardiorespiratory tnessIn cardiac rehabilitationCRwhich is our focus hereinpatients with coronary artery disease or chronic
heart failure undergo supervised exercise training to improve heart healthMost CR is performed in outpatient
settingswhere the lack of equipment and specially trained sta have precluded objective measurement of key
valuessuch as peak oxygen uptakeV O peakwhich is maximum V Oattained by the patient in a particular
exercise stress testwhich is not necessarily her his maximum attainable VOMeasurement of VO peak is desired
for tracking CR progress and for prescribing exercise intensitiesDue to its nonavailability in most outpatient
settingssuboptimalsemi quantitative substitute measurese gheart rate reserveBorg ratings of perceived
exertionorminute walk testare often employedAdditionallywith measurement of VEthe e cacy of CR
at improving measures of breathing e ciencye gthe ratios VE VCOand VE VOcan be computedwhich
is especially important for patients with high initial valuesLike VO peakthese e ciency metrics are seldom
available in CR practice due to equipment and personnel limitationsTo obtain such measurespatients have
to be scheduled for a cardiopulmonary exercise testCPETwhich is expensive andbeyond an initial testgenerally not covered by insuranceThe proposed Mobile Metabolic MeasurementMsystem will overcome
these limitations and can be used during CR exercise sessions to track patient progress on a frequent basisObjectively measured VO peak values can be usedalong with heart rateto optimize exercise prescriptions to
enable maximum safe progressThe Msystem will o er a huge advance in quantitative CR patient monitoringThe Msystem is a novelcost e ectiveportable device for accurately and reliably measuring V OV COV EV E V COV E V Othe respiratory exchange ratioR V COV Oand EEe gMETS or kilocaloriesThe proposed Msystemandapos s \one buttonandquotturnkeycalibration free operation and order of magnitude lower
price compared to existing cart or mobile indirect calorimetry systems will make it practical and a ordable for
use by non experts in outpatienthospitallaboratoryeldeducationaland even home settingsIn addition to
CRother areas that could bene t from the Msystem include assessing the resting metabolic rateRMRof
acutely ill and critically ill hospital patients to guide enteral and parenteral nutritionmonitoring the ventilatory
status of patients being weaned from mechanical ventilatorsand guiding weight loss by quantifying the impact
of dietary and exercise regimensMetabolic measurement is presently infeasible in many such applications Project Narrative
The proposed Msystem will address the current gap in the availability of an inexpensiveeasy to useand
accurate system for measuring V O peakV E V COV E V Oand R in cardiac rehabilitationCRsettings for
tracking patientsandaposphysiological responses to exercise and optimizing their exercise prescriptionsIt is well
documented in the literature that the key limitations of the gold standard cardiopulmonary exercise testCPETare directly related to the expertise required to perform the test and its associated costsboth equipment and
personnelEven outside of CR applicationsthe proposed Msystem represents a transformative technology
that will not only compete in existing marketsbut will contribute to the creation of new marketse gteam
sportshealth and wellness applicationsetcwhich will further drive down its cost
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Research funding history
331 SBIR/STTR records share this UEI (1987–2025). Reported award amounts total $130,507,041. Reported amounts are not federal obligations.
Phases: Phase I, Phase II, Phase II – Direct to Phase II
Agencies: Department of Defense, Department of Health and Human Services, National Aeronautics and Space Administration, Department of Commerce, Department of Education, Department of Energy
Contractor profile
BARRON ASSOCIATES, INC.
Historical federal award activity, when published, is on that contractor profile. Matched by UEI only.
Agency intelligence
Department of Health and Human Services
Back to SBIR/STTR Research Awards