SBIR/STTR Research Award

A Rapid, Near Patient System for Small Blood Volume Testing of Ammonia, Glutamine and Glutamate to Support Recurrent Monitoring of Acute Neonatal Hyperammonemia

Award identifier f299a4d0988d22686590d00ed141bf40956ee0ae3183594d681c05e902e3f873Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$231,134

Program and phase

SBIR · Phase I

Award year

2018

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
BAEBIES, INC.
Proposal award date
2018-07-05
Contract end date
2019-06-30
UEI
NZSZBQ9B84T1
Solicitation number
PA16-302
Topic code
NICHD

Research abstract

ABSTRACT A RapidNear Patient System for Low Blood Volume Testing of AmmoniaGlutamine and Glutamate toSupport Recurrent Monitoring of Acute Neonatal HyperammonemiaSBIR Phase IIn newbornshyperammonemiaplasma ammonia andgtmol Lis often the first symptom of an underlying urea cycle disorderUCDfatty acid oxidation defect or severe liver diseaseand affects an estimatedinbirthsClinical symptoms may present as early as the first few days of life andwithout prompt medical attentioncan rapidly lead to serious brain injury or deathAcute treatment for hyperammonemia includes simultaneous diagnostic evaluation to distinguish the physiologic basis for ammonia accumulation and therapeutic interventions to reduce plasma ammonia levels and prevent permanent neurologic damageGiven the potential severity of symptoms and the rapid rate of disease progressionexpedited testing is vital to the survival of affected newbornsUnfortunatelydiagnostic testing for hyperammonemia is currently challenging in newborns due to the relatively large blood volumeandgtmLneeded for multiple analytesthe requirement for recurrent testing during therapy and technical limitations for ammonia assaysThere is a compelling need for better methods to rapidly diagnose and monitor hyperammonemia in newborns using low blood volumesWe propose to develop a novel digital microfluidic systemFINDERfor the rapidnear patient measurement of ammoniaglutamine and glutamate in newborns from very low volumes of whole bloodandltl for all assaysGlutamine and glutamate are critical for ammonia homeostasis and serve as useful biomarkers in certain UCDsThrough this Phase I SBIR projectwe will develop sensitiveautomated assays capable of measuring all three analytes withinminutesThe FINDER Hyperammonemia test panel will allow clinicians to perform repeated testing during acute treatment of blood volume limited neonates without increasing the risk for iatrogenic anemiaThe Phase I Specific Aims includedevelop novel enzymatic assays for ammoniaglutamine and glutamate measurement using the FINDER digital microfluidic cartridgeoptimize assay conditions and determine preliminary analytical sensitivity and specificityandfeasibility demonstration using patient plasma samplesThe key milestone for progression to Phase II will be the successful demonstration of all assays on cartridge with acceptable sensitivity and precisionIn future Phase II effortswe will expand the panel to include additional analytesketonesglucose and or liver function testsestablish reagent drying protocols for the multiplexed assay and perform full analytical and clinical validationsWe will seek FDA approval of the final productwhich will initially be marketed for use in newborn patients in U Shospitalswith a potential future market towards older patients with known metabolic disorderswho may benefit from the rapidlow blood volume features of the platform PROJECT NARRATIVE Neonatal hyperammonemia caused by elevated blood ammonia levels is often indicative of a metabolic disorder and leads to devastating neurological effects or death if not detected and treated in a timely mannerMeasurement of plasma ammoniaglutamine and glutamate is indicated only after the presentation of symptomsand general chemistry laboratories in smaller hospitals or underdeveloped areas countries are often not equipped with the necessary equipment to measure ammonia or plasma amino acid levelsGiven the severity of symptomsearly detection and treatment of hyperammonemia is vital to the survival of affected newbornsThere is a compelling need for a near patient testing platform to quickly identify newborns with elevated ammonia levelsand for recurrent monitoring of ammoniaglutamine and glutamate levels during acute disease treatment

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

45 SBIR/STTR records share this UEI (2014–2025). Reported award amounts total $42,450,057. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.