SBIR/STTR Research Award

Replacing NaI with CdZnTe in Radioxenon Detectors for Nuclear Explosion Monitoring

Award identifier 014bf2a342e5b9714e2cdd397e2fe7b38a3203730c704e043bc0d2a9375f0d5dAwarding agency Department of Energy

Award amount

$150,000

Program and phase

SBIR · Phase I

Award year

2018

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
H3D INC
Proposal award date
2018-07-02
Contract end date
2019-04-01
UEI
KF7VYKHNEVN5
Solicitation number
DE-FOA-0001771
Topic code
01d

Research abstract

Radioxenon collection and monitoring provide valuable information about nuclear weapon testing and nuclear power accidents via 80 radionuclide detection stations around the world. Radioactive xenon is produced via nuclear reactions in nuclear reactors or nuclear weapons. However, the ratios of xenon isotopes vary based on the production mechanism, so by accurately quantifying these ratios, the source of the radioxenon can be ascertained. Current detection systems use sodium iodide (NaI) scintillators to detect photons in coincidence with a plastic scintillator to detect beta particles in order to reduce background. However, NaI detectors have relatively poor energy resolution which increases the likelihood of recording a false positive. Furthermore, the photomultiplier tubes used to read out NaI detectors are known to drift as a function of temperature, reducing the accuracy of the energy measurements, especially when the detectors are deployed in challenging environments. Semiconductor detectors inherently offer better energy resolution. CdZnTe, an alternative room- temperature semiconductor detector, has the same effective atomic number as NaI, and therefore the same efficiency per unit volume. The gamma-ray energy resolution of CdZnTe is seven times better than NaI at 662 keV which will reduce the minimum detectable concentration of radioxenon in a sample, improving international authorities’ ability to sense nuclear weapon detonations. In the first phase of this effort we will develop a drop-in direct replacement of NaI gamma-ray detectors with CdZnTe in existing radioxenon sensors. This will improve the sensitivity of the instruments to radioxenon, increasing authorities’ ability to detect smaller nuclear weapons tests. We will also examine alternate detector geometries for further improvements.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

22 SBIR/STTR records share this UEI (2014–2025). Reported award amounts total $9,784,996. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Energy, Department of Defense, Department of Commerce

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.