Explore This Research Award in CaptureIQ
Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.
Award details
- Awarding agency
- National Aeronautics and Space Administration
- Branch
- Not reported
- Recipient company
- SOUTHWEST SCIENCES INC
- Proposal award date
- 2018-04-17
- Contract end date
- 2020-04-16
- UEI
- Y7BFRF1G8539
- Solicitation number
- SBIR_17_P2
- Topic code
- S1
Research abstract
Over the past decade, the importance of understanding the sources and sinks of carbon dioxide and othergreenhouse gases has been recognized. A variety of research studies funded by NASA, DOE and NOAA tomeasure the fluxes of CO2 from average conditions have been performed. In particular, flux measurements ofCO2 in the boundary layer are critical toward understanding the carbon budget for this important greenhouse gas.The World Meteorological Organization has met its goal of 0.1 ppm CO2 accuracy for land based field sensorswith gas chromatography and nondispersive infrared instruments. However, these instruments are poorly suited for small aerial platforms because of their high power requirements, large size and/or weight specifications. This proposal directly addresses NASA's need for high accuracy, small aerial platform, CO2 instrumentation for their Sierra and Dragon Eye UAVs, other unmanned aircraft such as launched and tethered balloons, and remote, unattended ground platforms where low power, compactness and self calibration are important. This instruments fits in with NASA's Technology Roadmap for satellite validation under the ASCENDS program and the OCO2mission, as well as independent high resolution, nonintegrated CO2 profiles.To address this instrumentation need, Southwest Sciences has developed a compact (< 1 L), low power (< 2 watts), light weight (<1kg) diode laser based instrument to measure dry air corrected CO2 concentrations. Phase I was successfully completed. We achieved the Phase III targets in Phase I with a drift accuracy of <1 ppm at >1 hr andshort term precision of 0.2 ppm at 1 second under static conditions. Over a 300 torr pressure range, 12°C temperature range, and 1.6% water addition, the system successfully measured within a standard deviationof 0.7, 0.8 and 0.4 ppm respectively of the actual concentration. The source of deviation was well characterized in Phase I and can be further reduced in Phase II.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Research funding history
258 SBIR/STTR records share this UEI (1987–2025). Reported award amounts total $60,611,964. Reported amounts are not federal obligations.
Phases: Phase I, Phase II
Agencies: National Aeronautics and Space Administration, Department of Energy, Department of Defense, National Science Foundation, Department of Commerce, Department of Health and Human Services
Agency intelligence
National Aeronautics and Space Administration
Back to SBIR/STTR Research Awards