SBIR/STTR Research Award
Shoe insert to measure axial and shear forces as well as temperature at 42 locations in the insert and send data by wireless transmission to a PC, smart phone or other wireless devices.
Award amount
$150,000Program and phase
SBIR · Phase IAward year
2018Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- RTC Electronics Inc
- Proposal award date
- 2018-03-05
- Contract end date
- 2020-02-29
- UEI
- Not reported
- Solicitation number
- PA17-302
- Topic code
- 200
Research abstract
PROJECT SUMMARY ABSTRACT
Diabetic foot ulcers are extremely costly and debilitatingThe cost of care doubles in patients with diabetic foot
ulcers compared to patients without ulcersEven if an ulcer healsthere is arisk there will be a
recurrence within one yearso the problem is not likely to go away once it has startedThe presence of ulcers
and the potential necessity of an amputation both lead to dramatic decreases in both the quality of life and
overall health of people with diabetesThe biomechanical and physiological etiology of diabetic ulceration is
associated with damaging magnitudes of plantar pressuresshear forces and temperatures within inadequate
or ill fitting footwearPrevention strategies are needed that target all of these modifiable factorsHowevertodatecommercially available clinical systems used to measure the plantar surface only capture plantar
pressuresand do not quantify shear forces or temperature of the environmentCurrentlyif interventions or
advanced orthotics are designed to target skin damaging shear forces and temperaturesthese attributes
cannot be measured to validate and test the effectiveness of the interventionTo fill this considerable gap in
available technology in the care of diabetic patientsRTC ElectronicsInchas developed a uniquepatented
Multi Capacitor Sensor ArrayMCSAtechnologyIssued PatentsUSBand USBthat
can sense both axial and shear forcesquantify temperatureand can be fabricated on very thin flexible
substrates to fit within the footwearThe overall goal of the technology development proposed by RTC
ElectronicsIncis to develop a superior planter surface and foot function analysis system for clinical use to aid
in the evaluation of orthotics and interventions that prevent diabetic foot ulcersThe specific goal of this
application is to complete the initial development of our in shoe axial and shear forcepressureand
temperature sensorcomplete a thorough validation of the sensorand to gather feedback from the clinical
end users of the system on current and future design factors PROJECT NARRATIVE
Adults with diabetes and neuropathy in their feet often have foot ulcers because of walking barefoot and illfitted footwearCustom foot wearorthoticscan be made to prevent ulcers using force and pressure measure
sensors that fit inside a shoeThere are commercially available sensors currentlybut they do not measure all
the important variables including temperature and shear forceThis project will focus on developing an
advanced in shoe sensor that measures axial forceshear force and temperature to improve our ability to
prevent diabetic foot ulcers
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- Electromagnetic reprogramming of systemic metabolism for the treatment of type 2 diabetes
- Next-Gen Oral Therapeutics for Type 2 Diabetes
- Oral Therapeutics Platform for Treating Inborn Errors of Amino Acid Metabolism
- Development of novel therapeutics for obesity and type 2 diabetes
- Metrifonate local application for DFU treatment