SBIR/STTR Research Award

SBIR Phase I: Subcutaneous vascular access device that allows hydraulically controlled on demand access to blood flow for hemodialysis

Award identifier 31074cdeddfc7fc11d204aaf73738d457ba82ec1ddf89b3a0d2d9a8ec2d2943cAwarding agency National Science Foundation

Award amount

$225,000

Program and phase

SBIR · Phase I

Award year

2018

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
National Science Foundation
Branch
Not reported
Recipient company
Pharmateck LLC
Proposal award date
2018-01-01
Contract end date
2018-12-31
UEI
Not reported
Solicitation number
Not reported
Topic code
BM

Research abstract

The broader impact/commercial potential of this Small Business Innovation Research (SBIR) Phase I project is to improve the lives of over 500,000 patients with end stage renal disease receiving thrice-weekly hemodialysis treatments in the US each year. Hemodialysis requires the blood of a patient to be removed and passed through a filter for cleaning prior to returning it to the patient. Oftentimes patients receive insufficient dialysis treatments because the traditional blood pathways cannot be effectively sustained. This leads to increased infections, hospitalization rates and deaths. In addition to the unnecessary suffering of patients, the cost of maintaining these blood pathways is over $2B annually. This implantable device will improve our technical and scientific understanding of hemodialysis shortcomings and may lead to advancing the knowledge in medical fields related to arterial and venous access. This innovation will allow enhanced hemodialysis treatments for this vulnerable patient population by maintaining blood pathways and lowering infection rates. The proposed project is to create a vascular access device which ensures that end stage renal disease (ESRD) patients have reliable vascular access without the need for an arterialized venous system. AV fistulas and AV grafts often fail to mature and are associated with suboptimal long-term patency rates resulting in a loss of the patient?s life line to dialysis. The objective would be to create a completely subcutaneous device which can be anastomosed to an artery and a separate vein such that the arterial device can obtain a blood flow of at least 400ml/min and the venous device can return the dialyzed blood at a rate of at least 400 ml/min. The device must allow blood flow through its lumen only when needed and return the native vasculature to its normal flow state after each use. The technical difficulty is how to configure the mechanics of the device and its anastomosis to blood vessels in a manner which allows it to be opened and closed on demand without causing thromboses to form within the native vessels or device. We will be using computational fluid dynamic modeling and an iterative design process to achieve our prototype.

Technology keywords

Not reported

Agency intelligence

National Science Foundation

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.