SBIR/STTR Research Award

Safety and Efficacy of a Titratable External Shunt

Award identifier 6c31eec59b5b686ee200ea72d03b8277a98d307707a9767e2eca995de28d9ab4Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$886,057

Program and phase

SBIR · Phase II

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
CAMRAS VISION, INC.
Proposal award date
2017-09-30
Contract end date
2019-06-30
UEI
CLLKJRDMUC49
Solicitation number
PA15-269
Topic code
W

Research abstract

Glaucoma is a diverse group of chronic diseases that causes irreversible damage to the optic nerve and is a leading cause of blindness affectingmillion people worldwideIt is estimated thatinpeople who receivepropertreatment for glaucoma still experience loss of visionThe only proven method of treating glaucoma is to reduce the pressure in the eyeIntraocular PressureIOPAdvanced glaucoma must achieve IOP in the low teens to stop progressionUnfortunatelyless invasive therapies like anti glaucoma drugs and laser surgery do not commonly achieve these low IOPsthereforesurgical intervention is requiredStandard glaucoma surgeries are suboptimal with unpredictable outcomes and high complication ratesCamras Vision has created a biocompatible microchannel shunt capable of regulating IOPOur preliminary data demonstrate that the prototype can be used to set in vitro pressure based on the number and length of microchannels within the outlet tubeThe key to the Camras Shunt s success is its design to drain aqueous humor externallytherebyavoiding failure due to scarring within the drainage site associated with all other glaucoma surgeriesIn this Fast Track applicationwe will create a new generation shuntthe Titratable Camras ShunttCSto enable precise control of IOPIn Phase Iwe will construct a tCS prototype consisting of two outlet tubesinitially sealed with sutureseach containing a single microchannelthat allows for noninvasive manipulation postoperativelyOpening and closing of individual tubes controls and adjusts the target IOP rangeAdditionallythe tubes can be trimmed inmm increments to fine tune the IOP postoperativelyIn vitro fluid dynamic testingAimwill be used to assess the ability to set pressure ranges tommHg with one open channel andmmHg with two open channelsand to use tube trimming to reduce resistancewith each cut of the outlet tubeThe feasibility of precisely controlling IOP in vivoAimwill be assessed in cynomolgus monkeyswhich exhibit similar ocular fluid dynamics as humansovermonths in partnership with DrCarol TorisUniversity of Nebraska Medical CenterSuccess and justification for progression to Phase II will be indicated by the ability to set in vivo IOPs tommHg andmmHgmaintain IOP lowering in amonth follow up periodIOP does not increase more thanmmHgreduce IOP bywith tube trimming with no evidence of adverse effects to the monkeysIn Phase IIwe will optimize scale up manufacturing in partnership with Sil Pro Medical Manufacturing SolutionsThe manufactured devices will be tested after sterilizationby radiation or ethylene oxidebased on FDA guidelines forAqueous ShuntskSubmissionswhich will first include flowstabilityuniformityand mechanical testing at Camras facilitiesAimBiocompatibility toxicity testing to evaluate safetyAimwhich includes systemic toxicitygenotoxicitychemical testingandmonth rabbit ocular biocompatibility assessmentswill be conducted at NAMSAa GLPgood laboratory practiceapproved CRO with extensive ophthalmic experienceSuccess will be indicated if the final form tCS meets or exceeds guidelines set forth by the FDA for Aqueous Shunts to enable Camras Vision to submit akapplicationOnce commercializedwe anticipate that the tCS will make glaucoma surgery as accessible as cataract surgerywhich is known for its elegant surgeryeffectivenessand minimal complicationsMoreoverthe proposed shunt should enable ophthalmologists to target IOP with a quick and simple procedurestube opening and trimmingthat can be maintained via routine follow up outpatient visits

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

6 SBIR/STTR records share this UEI (2012–2017). Reported award amounts total $2,375,458. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.