SBIR/STTR Research Award

Development and Validation of SafeClose Mesh Augmentation System for Hernia Prevention

Award identifier f0d09ae227c3d8bfbf1bb86b6cdbee7dbeb7db2d45d0cda30a55a1adb0bcd3cfAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$243,070

Program and phase

STTR · Phase I

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Paradigm Surgical LLC
Proposal award date
2017-09-20
Contract end date
2018-09-19
UEI
KUDAYJK9M7K7
Solicitation number
PA16-303
Topic code
300

Research abstract

Incisional hernia IH can be prevented using prophylactic mesh placement PMP which involved placement of mesh to reinforce an abdominal fascia closure before herniation occurs at the index of surgery PMP reduced the absolute risk of IH with an acceptable complication profile Open abdominal surgery techniques remain commonplace and contribute to the estimated cases of IH performed in the United States US and the associated $ billion spent on hernia treatment To reduce these hernias more widespread adoption of PMP is needed yet barriers exist to adopting PMP in practice Surgeon level barriers are a key impediment due to the added time for PMP minutes A rapid mesh application system can reduce this time and increase utilization of PMP Further the reliability and technical challenges inherent to PMP pose significant challenges These barriers highlight an unmet clinical need for an effective well engineered intra operative technology to decrease the time and circumvent the technical challenges of applying mesh to the abdominal wall fascia for hernia prevention The SafeClose Mesh Augmentation System is a medical grade hand held mesh affixing system The system increases the speed of mesh affixation and circumvents technical intra operative challenges by integrating several key steps of the PMP process including positioning tensioning and affixation into one system The system includes sterilized mesh with pre integrated fastener anchors along with a customized applicator that houses the mesh fastener system inside By pulling the applicator along the length of the incision the mesh rolls out of the applicator and is simultaneously affixed by the fasteners In one continuous motion the entire incision can be reinforced When the surgeon reaches the bottom of the incision he she can cut the mesh off using the built in cutting mechanism This newly updated design satisfies important end user needs by providing an ergonomic yet robust application mechanism while at the same time allowing the device to accommodate for different incision lengths and sizes giving the user full ability to control the length of mesh that is used We propose a feasible systematic and step wise approach to refinement and proof of concept for the SafeClose System Success of this Phase I proposal will be defined by creation of a refined applicator whose core functionality includes a built in cutting mechanism to reliably and safely cut the mesh after the surgeon has completed the procedure AND demonstration that the SafeClose significantly reduces the time relative to a hand sewn technique Aim Experiment while achieving equivalent or improved biomechanical strength of the repair Aim Experiment The proposed research objectives will advance hernia care and begin a shift towards more preventative risk reductive interventions in abdominal surgery Development and Validation of the SafeClose Mesh Augmentation System for Prevention of Incisional Hernia Incisional hernia IH can be prevented using prophylactic mesh placement PMP however barriers to adoption of PMP in practice exist The SafeClose Mesh Augmentation system solves the technical challenges and added time associated with PMP by integrating several key steps of the PMP process including positioning tensioning and affixation into one system

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

4 SBIR/STTR records share this UEI (2017–2020). Reported award amounts total $2,192,592. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.