SBIR/STTR Research Award

Ureteral Stent Electromagnetic Removal USER Device for Pediatric Patients

Award identifier 5f84f7c2dc5850d7465e835fa5cfa1a94d862080356a11de9cd8230138d24953Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$224,692

Program and phase

SBIR · Phase I

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
FANNIN PARTNERS LLC
Proposal award date
2017-09-01
Contract end date
2019-08-31
UEI
DAHAYJEBV8K1
Solicitation number
PA16-302
Topic code
400

Research abstract

PROJECT SUMMARY Significance Over children have ureteral stents placed each year to alleviate an obstruction caused by a kidney stone between the kidney and the bladder or to maintain urinary flow following reconstructive or transplant surgery In adults a dangler string that is threaded through the urethra and secured to the skin is simply pulled at a follow up visit to remove the stent but this string is removed in children to prevent infection and accidental removal Children must then undergo an invasive procedure via cystoscopy which consists of inserting a scope into the urethra under general anesthesia to pull the stent out Recent evidence suggests early overexposure to anesthesia has been associated with an increased risk of long term cognitive deficits in language and abstract reasoning As such medical solutions that can provide the same results as traditional procedures without general anesthesia are being sought out in all areas of medicine but particularly in pediatrics Innovation The Ureteral Stent Electromagnetic Removal USER device is a non invasive stent removal system that uses a magnetic bead and an external electromagnet to smoothly guide the stent out of the patientandapos s body without the need for general anesthesia The magnetic bead is coated in a biocompatible material and is secured to the lower stent curl by tying the bead to the dangler string and cutting it short so that the bead and string remain in the patientandapos s bladder The electromagnet is held in a patient friendly casing with smooth surfaces and handles for ease of manipulation This solution shortens the removal process reduces the cost of the procedure and minimizes the risk of cognitive deficits in children from early overexposure to general anesthesia Approach In this SBIR Phase I project Fannin Innovation Studio will optimize the prototype device design and test it in benchtop animal and cadaver models of the urinary tract The Specific Aims of this project are Build and characterize a prototype USER device including magnetic beads and electromagnet with adjustable field strength The performance of various magnet geometries materials and coatings will be characterized and implemented into the prototype The field geometries of the electromagnet will then be evaluated and a user interface to control the magnetic field strength will be built Test the prototype USER device in benchtop animal and cadaver urinary tract models The previous benchtop model will be refined to be more anatomically representative of the pediatric urinary tract with respect to material elasticity and surface characteristics The prototype will then be tested in porcine and cadaver models to assess for signs of tissue damage and further demonstrate the feasibility of the device in living tissue We believe that the USER device will bring value to pediatric patients providers and childrenandapos s hospitals by providing a solution for stent removal that reduces the use of costly OR resources shortens surgeon procedure time and eliminates the risk of cognitive deficits from overexposure to anesthesia in children PROJECT NARRATIVE Ureteral stents are used to relieve obstructions and maintain urinary tract flow following transplant or reconstructive kidney surgery but they must be removed via cystoscopy in children which usually requires general anesthesia Recent evidence indicates that early overexposure to anesthesia in children can lead to long term cognitive deficits and as such medical solutions that are as effective but avoid unnecessary exposure to anesthesia are being sought out in all areas of medicine The USER device utilizes a magnetic bead that is tied to the end of the stent and an external electromagnet to gently pull the stent out through the urethra without the need for cystoscopy or general anesthesia

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

15 SBIR/STTR records share this UEI (2017–2025). Reported award amounts total $10,167,978. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.