SBIR/STTR Research Award

Multi Measure Speech Perception in Noise MMSPIN Chart More Scores Fewer Tests

Award identifier 6c2b46f9391244c9cb1fad7676cc3ed50e4760a8d3e39730e148d4abd4478f7cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$147,919

Program and phase

SBIR · Phase I

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
SeeHear LLC
Proposal award date
2017-09-01
Contract end date
2019-08-31
UEI
NNGGL4HBEAW1
Solicitation number
PA16-302
Topic code
NIDCD

Research abstract

Project summary This Phase I will establish the feasibility of increasing audiological diagnostic information by carrying out word and phoneme level analyses of open set responses during speech audiometry and by obtaining subjective hearing measures Speech audiometry is used in characterizing functional hearing in settings of hearing screening diagnosis hearing aid fitting counseling aural rehabilitation training occupational fitness and research A typical procedure used with word and sentence tests in background noise is to ask the client patient to repeat back what was just said i e give an open set response Responses are then scored in terms of words or keywords correct incorrect This method discards potentially diagnostic information in response errors because noise can reveal systematic phonetic feature or phoneme confusions and with background babble intrusions from the babble Other response patterns attributable to cognitive or memory declines may manifest in the paucity or verbosity of response words Specific types of phoneme perception errors are thought to be associated with extent and configuration of hearing loss and different types of noise maskers i e energetic and informational maskers present different types of perceptual problems that vary in severity across individuals In order to utilize response errors computational methods are needed to establish their relationships to the stimulus This is because response errors may incorporate incorrect stimulus to response phoneme substitutions as well as insertions or deletions of phonemes or words relative to the stimulus We have developed sequence alignment methods to mine errors during speech audiometry which we propose to evaluate using our system Multi Measure SPIN Chart MMSPIN Chart MMSPIN chart will be further developed and installed in the George Washington University Speech andamp Hearing Center Aim Audiologists will use the system during QuickSin sentence and NU word testing with clients years of age who give permission to access their entire clinic records Aim Their conventional speech audiometry will be augmented by obtaining subjective hearing accuracy judgments and hearing self efficacy measures These subjective judgments are designed to expose discrepancies with objective performance and to reveal individual differences in social cognition associated with hearing loss both of which may account for the large individual differences in performance and intervention outcomes not accounted for by the audiogram Evaluation of results in Aim will include developing group and individual profile models comprising objective and subjective clinical data With our clinician partners we will develop formats for communicating MMSPIN Chart results to clients In Aim we will present results in a public lecture for audiologists and solicit opinions about how our new results may best impact clinical practice Our approach can deliver more informative and efficient speech audiometry using existing test materials and can pave the way to more sensitive speech audiometry including tests that are adaptive to specific levels of speech processing difficulty Narrative The typical approach to speech audiometry is to elicit open set responses that are scored in terms of words keywords correct discarding information in response errors This Phase I will establish the feasibility of increasing diagnostic information provided to audiologists by carrying out word and phoneme level analyses of open set responses and obtaining subjective hearing measures in conjunction with speech audiometry The goal is to improve clinical efficiency and effectiveness and to improve patient outcomes

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2017–2019). Reported award amounts total $1,297,422. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.