SBIR/STTR Research Award

Rapid Assessment of Distribution Line Damage via Autonomous UAV

Award identifier 18026db146854ddcaf933ca208bc5762931cf99618bd0f5a5b4d0212c65a1522Awarding agency Department of Energy

Award amount

$146,530

Program and phase

SBIR · Phase I

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
BRAINS4DRONES LLC
Proposal award date
2017-06-12
Contract end date
2018-06-11
UEI
S64ZGNFJFS53
Solicitation number
DE-FOA-0001619
Topic code
05b

Research abstract

Two-thirds of all electric outage minutes are weather-related, mostly the result of damage to above ground distribution lines. These outages close schools, shut down businesses and impede emergency services, costing the U.S. economy between $18 and $33 billion per year. Efforts to restore power start with the utility’s evaluation teams driving through flooded, icy, blocked, unlit roads to document the extent of storm damage to distribution lines. We propose an alternative method to rapidly assess line damage that will assist utility personnel to safely complete their mission. Evaluators often need access to hard-to-reach and unsafe locations after a storm. When this happens, they can launch an autonomous unmanned aerial vehicle (UAV) from their vehicle that will lock onto and follow the distribution lines. The UAV will use stereoscopic 3D depth perception to sense and avoid obstacles as it maintains a fixed distance from the overhead lines, collecting images as it travels the lines. Onboard algorithms will send a curated set of geo-tagged imagery to the Outage Management System (OMS). Other first responders can also be notified of unsafe conditions. In Phase I, we will develop pattern recognition algorithms to detect poles, crossarms and wires. We will analyze their geometry and flag anomalies that indicate structural damage, such as broken elements, downed lines or encroaching vegetation. In Phase II, we will detect more elements such as damaged pin-insulators, broken ties and blown fuses. We will also deploy our technology on the UAV and integrate with the OMS. Ultimately, the situational awareness provided by the UAV will reduce power restoration times by helping utilities prioritize repairs, better allocate resources and more efficiently deploy repair crews. While on standby, the UAV can be used for service calls, transmission line inspections, vegetation management, and substation monitoring.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

2 SBIR/STTR records share this UEI (2017–2018). Reported award amounts total $1,156,527. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Energy

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.