SBIR/STTR Research Award

A Graphene Nanoparticle Based X ray Computed Tomography Contrast Agent ForSubjects At Risk for Contrast Induced Nephropathy

Award identifier d6145695dfb08e74f357d911ad76319cd62a1a3aa585e2e36d460cd2bc549420Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$190,500

Program and phase

SBIR · Phase I

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Theragnostic Technologies Inc.
Proposal award date
2017-05-16
Contract end date
2018-05-31
UEI
Not reported
Solicitation number
PA16-302
Topic code
300

Research abstract

Abstract This SBIR phase proposal is to demonstrate the pre clinical safety and efficacy of a novel carbon nanostructure based X ray computer tomography CT contrast agent CA for imaging and monitoring in patients with renal failure or at risk of contrast induced nephropathy CIN Routine contrast enhanced CT scans relays crucial information about diseases and injuries thus aiding the clinician in improving diagnosis and management of patients The present day CT CAs available on the market are all based on covalently bonded tri iodinated benzene rings However they are all contraindicated for patients with renal insufficiency diabetes heart failure and thyroid dysfunction Use of these CT CAs in these patient cohorts has been linked to CIN which deteriorates normal or further exacerbate pre existing kidney functions These adverse effects have been associated with high osmolality and viscosity CT CAs and the inability of these and even low or iso osmolar and or iso viscous CT CA formulations to be completely eliminated of cytotoxic free iodine ions in solution The technology detailed in this proposal builds on our previously reported novel carbon nanoparticle based T iso osmolar iso viscous Magnetic Resonance Imaging MRI CA This comprises of manganese Mn intercalated graphene oxide nanoplatelets GNP covalently functionalized with dextran and named GNP Dex This formulation shows low acute toxicity high blood stability and high renal clearance through the urine For expanded multimodal use we intercalated and covalently functionalized iodine ions to the inner graphene sheet layers This method of sequestration of iodine prevents its dissociation as free ions into solution This formulation we termed GNP I In vitro studies done on kidney epithelial cell culture demonstrated favorable GNP I cyto compatibility Furthermore at equimolar concentration of iodine GNP I showed very high CT times greater radio opacity signals in phantoms compared to the control Iohexol Omnipaque a commonly used CT CA Thus these lower detection limits will allow the same clinical imaging performance at substantially lower dosages thus lowering healthcare costs Based on GNP I characteristics inclusive of its apparent higher safety and efficacy profiles than that of currently available CT CAs the thrust in this proposal is to develop it specifically for monitoring and diagnosis of kidney and other vital organs for patients at risk of CIN Thus thereby overcoming the limitations of present day CT CAs For this we will conduct pre clinical safety and efficacy feasibility studies in a well validated rodent model of acute kidney injury that is the Nephrex rat Successful completion of the aims outlined in this proposal will lead to submission of a SBIR phase proposal to perform safety and efficacy pre clinical studies in a suitable large animal model under good laboratory practice GLP followed by Investigational New Drug IND application to the FDA Furthermore successful development will lead to the first FDA approved CT CA specifically for use in these high risks distinctly disadvantaged patient groups Project Narrative Routine X ray contrast enhanced Computer Tomography CT scan is essential for preventative screening and detecting diseased pathologies however presently available contrast agents are contraindicated in patients with renal insufficiency diabetes heart failure and thyroid dysfunction these subjects being at risk for contrast induced nephropathy There is an urgent requirement for safe and efficacious CT contrast agents to address this unmet clinical need Our proposed technology is a novel nanoparticle based CT contrast agent for imaging and monitoring of vital organs in this high risk patient group

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.