SBIR/STTR Research Award

Improved pulse oximetry performance using transmission optical flowmetry

Award identifier 0088dca51c60c3cecbb9337ccb7a27fe89f3790ed09b89f27f8d08a8440755b8Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$149,237

Program and phase

SBIR · Phase I

Award year

2017

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Laser Associated Sciences
Proposal award date
2017-03-15
Contract end date
2018-03-14
UEI
Not reported
Solicitation number
PA15-269
Topic code
300

Research abstract

Project Summary Since its commercial introduction in pulse oximetry has become a widely adopted standard of care in operating rooms intensive care units and hospital wards The ability to measure arterial oxygen saturation using pulse oximetry is so useful that it is considered the th vital sign Despite their ubiquity pulse oximeters have suffered from two fundamental limitations since their inception poor signal quality when patients experience vasoconstriction and erroneous data caused by motion Although advanced signal processing techniques have been use commercially to address these problems false alarms that lead to increased staff workload and decreased vigilance alarm fatigue remain very common The long term goal of the proposed research is the development of a next generation pulse oximeter which addresses the limitations above by performing arterial blood oxygenation measurements in new and fundamentally different manner than the photoplethysmographic methods used today The proposed method leverages established blood flow measurement techniques based on light scattering to perform measurements which results in a signal that is often hundreds of times greater than a typical pulse oximeter signal and which is significantly less susceptible to vasoconstriction and motion This long term goal will be achieved by pursuing the following three specific aims integrating a multi wavelength VCSEL light source into an established clip on blood flowmeter validating this multi wavelength instrument in a rabbit model via comparison to bench top blood gas analysis during an oxygen challenge and completing a formal framework for relating SpO to measured blood flow waveforms using collected empirical data from in conjunction with Monte Carlo simulations Aim will be accomplished by modifying instrumentation already developed by the PI to measure blood flow with multi wavelength light sources fabricated through a commercial partner Aim will be accomplished through close collaboration with the Beckman Laser Institute and their established veterinary team who performs photonics based small animal studies daily Aim will be accomplished by utilizing validated light propagation modeling tools to create a robust lookup table based generated from the data collected in Aim Project Narrative Pulse oximeters are ubiquitous in healthcare but suffer from major inaccuracies during critical periods of low pulse pressure and motion LAS has proposed a novel flowmetry based oximeter which is superior to traditional intensity based methods because it retains high signal fidelity during low perfusion and motion Improving the accuracy of oximeters during adverse conditions will improve patient outcome and ease the workload for caregivers by reducing false alarms

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.