SBIR/STTR Research Award
Improved pulse oximetry performance using transmission optical flowmetry
Award amount
$149,237Program and phase
SBIR · Phase IAward year
2017Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- Laser Associated Sciences
- Proposal award date
- 2017-03-15
- Contract end date
- 2018-03-14
- UEI
- Not reported
- Solicitation number
- PA15-269
- Topic code
- 300
Research abstract
Project Summary
Since its commercial introduction in pulse oximetry has become a widely adopted
standard of care in operating rooms intensive care units and hospital wards The ability to
measure arterial oxygen saturation using pulse oximetry is so useful that it is considered the th
vital sign Despite their ubiquity pulse oximeters have suffered from two fundamental limitations
since their inception poor signal quality when patients experience vasoconstriction and
erroneous data caused by motion Although advanced signal processing techniques have been
use commercially to address these problems false alarms that lead to increased staff workload
and decreased vigilance alarm fatigue remain very common
The long term goal of the proposed research is the development of a next generation
pulse oximeter which addresses the limitations above by performing arterial blood oxygenation
measurements in new and fundamentally different manner than the photoplethysmographic
methods used today The proposed method leverages established blood flow measurement
techniques based on light scattering to perform measurements which results in a signal that is
often hundreds of times greater than a typical pulse oximeter signal and which is significantly less
susceptible to vasoconstriction and motion
This long term goal will be achieved by pursuing the following three specific aims
integrating a multi wavelength VCSEL light source into an established clip on blood flowmeter
validating this multi wavelength instrument in a rabbit model via comparison to bench top blood
gas analysis during an oxygen challenge and completing a formal framework for relating
SpO to measured blood flow waveforms using collected empirical data from in conjunction with
Monte Carlo simulations Aim will be accomplished by modifying instrumentation already
developed by the PI to measure blood flow with multi wavelength light sources fabricated through
a commercial partner Aim will be accomplished through close collaboration with the Beckman
Laser Institute and their established veterinary team who performs photonics based small animal
studies daily Aim will be accomplished by utilizing validated light propagation modeling tools to
create a robust lookup table based generated from the data collected in Aim Project Narrative
Pulse oximeters are ubiquitous in healthcare but suffer from major inaccuracies during critical
periods of low pulse pressure and motion LAS has proposed a novel flowmetry based
oximeter which is superior to traditional intensity based methods because it retains high signal
fidelity during low perfusion and motion Improving the accuracy of oximeters during adverse
conditions will improve patient outcome and ease the workload for caregivers by reducing false
alarms
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- A platform for T-cell receptor mimic antibody generation modeled using pHLA-A*11:01 KRAS G12D
- Combinatorial pipeline for discovery of anti-GPCR Nanobodies
- Development of a GBP-based glycosylation analysis system
- Extended-release injectable gel for multi-day treatment of postoperative pain
- eMOA: A Multi-Omic Service for Mechanism of Action Determination in Drug Screening