SBIR/STTR Research Award

Advanced Urinary Catheter for Reduction of Urinary Tract Infections and Improved Urologic Management

Award identifier 533f9b59d42df98c76ebcacd0ebc0f36ed57fb51c622cd95c48e0f21f88a00e2Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$225,000

Program and phase

SBIR · Phase I

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
SPINAL SINGULARITY, INC.
Proposal award date
2016-09-20
Contract end date
2017-08-31
UEI
J9SNVYL97RM1
Solicitation number
PA15-269
Topic code
400

Research abstract

ABSTRACT Development of Advanced Urinary Catheter for Reduction of Urinary Tract Infections and Improved Urologic Management Catheter associated urinary tract infections remain an outsized problem in healthcare systems worldwide Individuals who rely on urinary catheterization for management of chronic urinary retention disorders are particularly susceptible to CAUTI because of their chronic usage This SBIR Phase proposal details plans by which to complete the prototyping design refinement and preliminary engineering validation of a new fully internal male urinary catheter system The Connected CatheterTM is an advanced urinary catheter designed to reduce the incidence of urinary tract infections UTI as well as to increase urological convenience and autonomy for males with urinary retention disorders The Connected Catheter will be a chronically indwelling maximum of day service life urethral catheter that resides fully internally with its distal end in the base of the penile urethra The catheter tip will incorporate a magnetically actuated ball valve which enables the bladder to fill naturally and the user to control voiding by applying a magnet to the base of the penis The Connected Catheter aims to reduce the risk of catheter associated UTI CAUTI via several mechanisms including elimination of the trans urethral orifice span of standard Foley and the use of a unique Malecot retention mechanism that provides robust catheter fixation and complete bladder emptying while minimizing bladder lining abrasion and risk of genito urinary trauma caused by Foley catheters Relative to intermittent self catheterization the Connected Catheter aims to reduce the risk of both UTI and false passage urethral puncture as well as lower the associated cost of supplies all by minimizing the number of self catheterizations required The Connected Catheter will offer increased comfort and convenience to all of its users enabling natural bladder filling and easy voluntary voiding all with a fully internal device that can be easily inserted and extracted by the user with a novel set of sterile packaged single use insertion and extraction tools The target deliverable of Phase will be a complete bench tested commercial prototype of the Connected Catheter system suitable for subsequent validation and clinical testing in Phase This proposed Phase project is divided into four specific aims including the successful fabrication design optimization and engineering validation of the magnetically actuated valve the catheter anchoring mechanisms the catheter insertion and extraction tools and the fully assembled product Future development of the Connected Catheter system beyond the current project will include the development and incorporation of a wireless sensor capable of assessing bladder fullness for users with neurogenic bladder dysfunction who lack bladder sensation PROJECT NARRATIVE Urinary catheterization is the current standard of care for millions of American men with chronic urinary retention disorders including benign prostate hyperplasia and neurogenic bladder dysfunction However current urinary catheter designs are plagued by a host of drawbacks and medical complications including high urinary tract infection rates genito urinary trauma and diminished patient quality of life due to inconvenience and discomfort We are developing a solution that uses a fully internal valved catheter to reduce the number of times users have to catheterize themselves By developing this product we aim to reduce infections reduce the costs of supplies and care and improve patient satisfaction

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

2 SBIR/STTR records share this UEI (2016–2018). Reported award amounts total $1,713,616. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.