SBIR/STTR Research Award

A Combination Endovascular Device Therapeutic Hypothermia with Stentriever Devices

Award identifier 742d11a70c3c7d521a4a58474bef58a865fa7a0b1a7d5c0eddf8d20c756cde4fAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$682,100

Program and phase

SBIR · Phase I

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Tom L Merrill
Proposal award date
2016-09-15
Contract end date
2018-09-30
UEI
Z2NHHMG3DKK5
Solicitation number
PA15-269
Topic code
106

Research abstract

Project Summary Stroke is the th leading cause of death and number one cause of adult disability in the United States The primary goal of ischemic stroke treatment is quickly restoring blood perfusion However studies have shown that this return of blood flow while necessary can also cause damage to local tissue Hypothermia has been shown to decrease this reperfusion injury The overall goal of our research is to couple therapeutic hypothermia to intracranial thrombectomy devices called stentrievers or stent retrievers Our device is a patented tissue cooling system that rapidly cools ischemic tissue at risk of reperfusion injury Our Phase I work will demonstrate ease of use and cooling effectiveness feasibility with a human scaled prototype rapid brain cooling during and after occlusion and brain tissue salvage and neurological benefit in a canine occlusion model Phase II will refine the design and prepare the technology for first in man studies Specific Aims Demonstrate ease of use and cooling effectiveness of FocalCoolandapos s CoolGuide cooling system with stent retrievers characterizing the cooling performance and ensuring safe operation in vitro Translate the human scaled prototype to a canine scaled version for in vivo testing Demonstrate safe cooling before and during reperfusion yielding infarct volume reduction and improved neurological outcome Cooling capability and stent retriever device integration will be determined using our in vitro circulatory system model To demonstrate the safety performance and efficacy of rapid localized brain tissue cooling in vivo studies will be conducted using an in vivo model of transient ischemic stroke Metrics of safety will include a decrease in core temperature no larger than C and safe maintenance of blood pressures and systemic hemodynamics during cooling Metrics for performance will include device ease of use with stent retrievers and tissue temperature reduction in at risk brain tissue regions during and after occlusion Metrics of efficacy will include reduction in infarct volume and neurological improvement compared to controls Relevance Effective recanalization with todayandapos s stent retrievers is a promising new standard of care for ischemic strokes Reperfusion injury however following recanalization continues to be an unmet problem in ischemic stroke care Approximately of stent retriever patients leave with modified Rankin Scores greater than indicating moderate disability to severe disability including death The technological innovation of combining stroke treatment therapies mechanical thrombectomy and precise well integrated reperfusion hypothermia may yield synergistic benefits resulting in reduced infarct size and improved long term neurological outcomes Both Medtronic and Stryker support this work Please see letters of Support Project Narrative Stroke is the th leading cause of death and number one cause of adult disability in the United States For stroke treatment quickly restoring blood flow has been shown to improve outcome yet some experts have found reperfusion injury reduces these benefits FocalCool LLC seeks to combine two technologies endovascular stentriever devices and therapeutic hypothermia using a novel localized tissue cooling system to maximize the benefit of blood flow restoration while minimizing the damaging effects of reperfusion injury

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

2 SBIR/STTR records share this UEI (2016–2019). Reported award amounts total $2,641,693. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.