SBIR/STTR Research Award

Microfabricated Cochlear Electrode Array

Award identifier 7e70f37560cb50a991d33e02c946725aa4fb54f3d8eb3df0781de80ae3b675d5Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,425,503

Program and phase

SBIR · Phase II

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MEMStim LLC
Proposal award date
2016-09-01
Contract end date
2019-08-31
UEI
NPHRMGVU99E8
Solicitation number
PA15-269
Topic code
NIDCD

Research abstract

Project Summary Abstract Current cochlear implants while beneficial in their use are limited in their capabilities by hand assembly of the electrode arrays This tedious manufacturing method is very costly extremely labor intensive and inadequate in implementing new technologies for improving speech recognition and music appreciation A superior alternative to hand assembly is microfabrication which is a fully automated low cost and high yield manufacturing process that is capable of implementing a variety of innovations including smaller array size for residual hearing preservation drug delivery channels for inner ear health and cell regeneration and strain gauges for improved performance during surgical insertion Microfabrication is a very promising alternative to hand assembly but has yet to meet the following requirements for commercialization substrates must be composed of proven long term implantable materials USP class VI electrode arrays must be compatible with standard surgical insertion techniques substrate and electrode sites must be able to withstand long term electrical stimulation in the body the array must be long enough to extend from the tip of the cochlea to the location behind the ear where the electronics are implanted under the skin and the array must have electrical wiring that is compatible with the electrical feedthrough pins of the implantable cochlear stimulator ICS During Phase I MEMStim showed that it is feasible to produce a microfabricated cochlear electrode array out of medical grade materials that can meet the commercial requirements The goal of Phase II will be to produce just such an array as a minimum viable product MVP for cochlear implant manufacturers The MVP will address requirements and further improve upon the Phase I results of requirement In order to accomplish the Phase II goal the following Specific Aims will be accomplished Aim produce a full length microfabricated cochlear array with an integrated cable that can be bonded to an implantable cochlear stimulator and complies with electrical mechanical durability biocompatibility and FDA safety requirements specified in communications with cochlear implant manufacturers and Aim produce a connector scheme for integrating a microfabricated cochlear electrode to the feedthroughs of an implantable cochlear stimulator The expected outcome is an array that can be integrated by customers into their cochlear implant systems and pass all handling use safety tests that cochlear implant manufacturers would need to seek approval from the FDA Project Narrative Cochlear implants allow the profoundly deaf to achieve reasonable word recognition in quiet environments but technological innovations to achieve fuller appreciation of music and speech are severely limited by the shortcomings of current hand assembly manufacturing methods for cochlear electrode arrays MEMStim LLC will develop a superior alternative to hand assembly microfabrication This novel method is a fully automated low cost and high yield manufacturing process capable of implementing technological innovations that will provide benefits such as small electrode array size for residual hearing prevention drug delivery channels for inner ear health and cell regeneration and strain gauges for improved surgical safety outcomes

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2014–2020). Reported award amounts total $3,093,854. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.