SBIR/STTR Research Award

Development of Intrasaccular Flow Disrupters for Small and Ruptured Aneurysms

Award identifier 4e88454f9dfca667f7720d3b8c338db639f660e281ab20b1e3a3719531fbc2b6Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,051,119

Program and phase

SBIR · Phase II – Direct to Phase II

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
SEQUENT MEDICAL, INC.
Proposal award date
2016-06-01
Contract end date
2017-05-31
UEI
Not reported
Solicitation number
PAR14-088
Topic code
101

Research abstract

DESCRIPTION provided by applicant The long term goal of this Phase SBIR program is to provide a highly effective minimally invasive treatment option for patients suffering from small broad necked intracranial aneurysms To address the unmet clinical need for treating small broad necked aneurysms Sequent Medical Inc has developed the Woven EndoBridge or WEB device The WEB represents a fundamental change in the treatment of this important subset of aneurysms in its current form developed under a previous Phase SBIR the WEB is readily placed into broad necked bifurcation aneurysms and results in rapid cessation of flow into the aneurysm without need for an intraluminal support device or antiplatelet therapy The original WEB received regulatory approval for use in European Union countries as well as Chile Argentina Colombia Australia and the United Arab Emirates and has been placed into more than aneurysms worldwide mostly in medium sized aneurysms it is currently being studied under an Investigational Device Exemption IDE trial in the US Current safety and efficacy data are highly promising Notwithstanding the substantial success of the original WEB important issues patient groups and markets remain to be fully addressed Application of the WEB device to small aneurysms both ruptured and unruptured has been limited because of the relatively large sized access catheters required to place the current WEB devices The current WEB devices require catheters substantially larger than standard microcatheters of andquot inner diameter microcatheters used to treat aneurysms Over the past two years the Sequent engineering team has made rapid progress in down sizing the profile of later generation WEB devices The newest WEB devices Single Layer SL and Single Layer Spherical SLS can be placed through customized microcatheters which are still too large to facilitate treatment of the most common sizes of ruptured aneurysms Thus we propose here to proceed with development of an innovative WEB device targeting treatment of small broad necked aneurysm including those that are ruptured This will entail re engineering the WEB device for use with microcatheters Aim and retesting the device in a standard model system with Dr Kallmes at the Mayo Clinic Aim Our experience with the original WEB stands as a Phase I equivalent proof of concept that WEB devices are feasible and of great medical utility indeed our original work was so rapidly completed that we proceeded with development phases independently rather than waiting for a Phase II SBIR Thus while independently pursuing an IDE on the original WEB device our originally intended Phase II we now propose a Direct Phase II to adapt the WEB for use in standard sized access catheters in aneurysms of any morphology and thus markedly expand the anticipated utility of the device At the successful conclusion of this Phase II SBIR we will be poised to study the newly adapted WEB device in an IDE Notably the progress of the current WEB model reduces the regulatory and technical risk for the development of this new device which would provide a breakthrough in the treatment of small broad necked aneurysms PUBLIC HEALTH RELEVANCE The goal of this program is to provide a highly effective minimally invasive treatment option for patients suffering from a dangerously weak blood vessel in the brain cerebral aneurysms Despite many advances in treating cerebral aneurysms small aneurysms with wide neck openings remain particularly difficult to treat With our success in creating an effective minimally invasive device the Woven EndoBridge or WEB to treat larger wide necked aneurysms Sequent Medical now proposes to address these smaller aneurysms including those that occur at blood vessel junctions bifurcated aneurysms or that have ruptured with a smaller and more versatile device system the WEB

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.