SBIR/STTR Research Award

Micropatterned surfaces for minimizing percutaneous gastrostomy tube complications

Award identifier 7d6fe297df0cabe87b2117cd45154b9bbc0964c13bd81099eb581051040e996eAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$173,587

Program and phase

SBIR · Phase I

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Sharklet Technologies Inc.
Proposal award date
2016-04-15
Contract end date
2017-04-06
UEI
Not reported
Solicitation number
PAR13-090
Topic code
NICHD

Research abstract

DESCRIPTION provided by applicant Enteral nutrition using feeding tubes provides a long term means of improving the nutritional status for infants and children with neurological syndromes cancer gastrointestinal disease cardiac disease and metabolic disease by allowing administration of feeding formula directly to the stomach through the upper abdomen More than pediatric percutaneous gastrostomy PG tubes are placed in US hospitals annually The majority of PG tube complications resulting in morbidity include microbial contamination tube clogging dislodgement and stomal complications Prevention of PG tube complications requires implementation of innovative biomaterials that are safe for vulnerable infant and child populations This directive is consistent with the NIH goals of improving human health as well as the specific NICHD goals of ensuring that all children have the chance to achieve their full potential for healthy and productive lives free from disease and disability In pursuit of those important goals Sharklet Technologies Inc proposes to incorporate a bio inspired Sharklet micropattern on pediatric PG tubes to significantly reduce bacterial contamination clogging displacement and stomal complications The anticipated impact of this technology is to reduce PG device failure thereby generally improving infant and child health for thousands and minimizing pediatric patient morbidity The Sharklet micropattern achieves these effects without the use of chemical additives or toxic compounds which is important for a pediatric population that is typically more sensitive to medical device surface chemicals The power of Sharklet is that the novel micropattern can be produced in the same approved biomedical materials used currently The improved PG device envisioned by the Sharklet Randamp D team is expected to reduce bacterial contamination that causes infections improve feeding formula flow to reduce clogging and enhance stoma formation to limit dislodgement and painful stoma site cellulitis The feasibility of attaining each of these improvements will be pursued by the expert Sharklet interdisciplinary team via two main Phase I SBIR Specific Aims {involving testing device prototypes with the Sharklet micropattern} Aim will focus on {implementing} the Sharklet micropattern to the PG tube lumen to reduce feeding formula accumulation by at least pandlt and microbial biofilm formation by andgt pandlt Aim will focus on {implementing} the Sharklet micropattern to the device exterior to promote at least pandlt faster in vitro epidermal keratinocyte migration and andgt pandlt thicker stomal wall formation in vivo Key preliminary work by Sharklet is a strong foundation for achieving these Aims Once Phase I SBIR milestones are met a follow on Phase II SBIR project will be focused on completing development commercialization of the Sharklet micropatterned PG device Sharklet Technologies has extensive experience in developing and commercializing medical devices previous incorporation of the Sharklet micropattern for {alternative mechanisms of preventing device complications} have been accomplished on a Foley urinary catheter and an endotracheal tube PUBLIC HEALTH RELEVANCE More than pediatric feeding tubes are placed in the US annually and they are associated with morbidity due to infections clogging dislodgement and stoma site cellulitis Sharklet Technologies Inc proposes to substantially reduce morbidity through incorporation of the Sharklet micro texture produced in the same silicone plastics currently in use which is especially important for pediatric populations where toxic chemicals and additives are not well tolerated The micro texture will reduce bacterial contamination that causes infections improve feeding formula flow to reduce clogging and enhance stoma formation to limit dislodgement and painful stoma site cellulitis

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.