SBIR/STTR Research Award

Actuated Low Stress Endotracheal Tube Cleaner to Improve Neonate Lung Function

Award identifier 08887ee01d0998f4ee925acae907f16f076b6aa1a7f78edd91d5701f8fa9894cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,499,960

Program and phase

SBIR · Phase II

Award year

2016

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ACTUATED MEDICAL, INC.
Proposal award date
2016-02-01
Contract end date
2020-01-31
UEI
VG84D4KN5LR5
Solicitation number
PAR13-090
Topic code
NICHD

Research abstract

DESCRIPTION provided by applicant This Phase II SBIR finalizes development and clinically tests Neo ET Clear an Actuated Low Stress Endotracheal Tube ETT Cleaner to Improve Neonate Lung Function Neo ET Clear suctions mucus from mm diameter neonatal endotracheal tubes with significantly reduced deleterious impact on lung function and mechanics as compared to current methods including Closed Suction Systems Public Health Problem ETTs are placed in neonatal patients annually in the U S Intubation is particularly common in NICUs in tertiary care referral sites which see a high number of complicated premature neonates and intubation rates as high as The ETT in the respiratory tract stimulates secretions and interferes with the patientandapos s ability to expectorate T remove secretions ETTs are regularly aspirated with suction catheters every hours The normal suctioning procedure is extremely uncomfortable and stressful to the patient Such pain and distress when occurring in neonates can affect brain growth and lead to long term developmental delays Immediate risks associated with standard suctioning include loss of lung volume and compliance desaturation hypoxia low blood oxygen decreased heart rate and changes in cerebral blood flow oxygenation Furthermore standard suction catheters can push secretion material possibly containing bacteria into the respiratory tract increasing the risk o lung infection Potential long term risks of repeated suctioning include chronic lung disease from occult atelectasis and retinopathy of prematurity due to large fluctuations in blood oxygen A device is needed for clearing neonatal ETTs that reduces the harmful side effects of standard suctioning methods on short and long term patient health and on lung function Neo ET Clear is an actuated closed suction system designed to safely and effectively suction neonatal and pediatric patients on mechanical ventilation The Neo ET Clear Suction Stem incorporates a controlled gentle vibration with internal irrigation that facilitates mucus removal The Stem is inserted in and out of the patientandapos s ETT similar to standard closed Suction Catheter The Phase I project met all Specific Aims demonstrating that Neo ET Clear dramatically reduced effects on test model lung mechanics x better maintenance of inspired Tidal Volume and PEEP loss of only compared to during closed suctioning of mm ETTs while achieving equal mucus removal and tidal volume restoration compared to standard Fr Closed Suction Catheters Feedback from practicing NICU clinicians was extremely enthusiastic Phase II Hypothesis Neo ET Clear is Safe for use in Neonatal Patients and Reduces the Negative Impact of Suctioning on Blood Oxygen Lung Mechanics and Patient Distress Aim Incorporation and validation of design and safety features into Neo ET Clear does not impact beneficial suctioning efficiency results Aim Demonstrate Safety and Improved Physiologic Outcomes with Neo ET Clear through Pre Clinical Testing Aim Pilot Human Clinical Evaluation Childrenandapos s Hospital of Philadelphia n PUBLIC HEALTH RELEVANCE A patient is intubated with an endotracheal tube and connected to a ventilator when they cannot breathe on their own Mucus builds up over time in the tube and must be suctioned out Neonatal endotracheal tubes with inner diameters as narrow as mm require frequent suctioning and are difficult to clean without obstructing the airway The suctioning puts significant stress on the lungs of an already compromised patient and impacts long term health A device for cleaning endotracheal tubes particularly pediatric and neonatal tubes without the negative impacts of current suctioning methods will be of great benefit

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

53 SBIR/STTR records share this UEI (2008–2024). Reported award amounts total $43,582,989. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation, Department of Defense, National Aeronautics and Space Administration, Department of Agriculture

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.