SBIR/STTR Research Award

Development of a Neurovascular Magnetic Particle Imaging system with sub-millimeter resolution and real time speed for non-radiative 3D perfusion angiography

Award identifier 158134240ff2b95e664736f806ba7d4452ff6c0eb3a8f10f6694f37195cab4bcAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$223,825

Program and phase

SBIR · Phase I

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MAGNETIC INSIGHT, INC
Proposal award date
2015-09-15
Contract end date
2016-08-31
UEI
HY76TZ1Z48X4
Solicitation number
PA14-071
Topic code
NIDA

Research abstract

DESCRIPTION provided by applicant There is a clinical need for new neurovascular imaging techniques for the diagnosis staging and monitoring of acute stroke and sub acute stenoses arterial venous malformations AVMs and aneurysms among others Together these etiologies frequently manifest in acute stroke and kill over people per year with an estimated cost the US healthcare system of over billion dollars per year A reliable and non invasive neurovascular stress test similar in concept to a cardiac stress test would revolutionize cerebrovascular imaging and stroke prevention It is well known that perfusion imaging combined with a means of altering cerebral perfusion pressure or cerebrovascular resistance can measure a patientandapos s cerebrovascular reserve and predict the risk of stroke Current neurovascular imaging techniques suffer from limitations in radiation exposure safety speed sensitivity and specificity that prevent their use in measuring cerebrovascular reserve Magnetic particle imaging MPI is a new imaging technology that answers a clinical need for a safe rapid D perfusion and D angiography technique without ionizing radiation or toxic tracers to image intracranial diseases such as stenosis stroke aneurysm vasospasms and malformations The MPI tracer is made with Iron Oxide SPIO significantly safer than Iodine used in CT and fluoroscopy and Gadolinum used in MRI The safe tracer and absence of harmful radiation leads to reduced long term medical costs for patient undergoing diagnostic angiography and especially patients undergoing repeated diagnostic angiography procedures associated with long term care MPI produces absolutely no signal from overlying tissues creating a positive contrast and quantitative angiography images or real time perfusion with unprecedented contrast to noise and signal to noise Successful completion of a human brain imager will mark the beginning of a new field of diagnostic imaging comparable in scope to the introduction of MRI CT or Ultrasound This project aims to develop the first high resolution real time MPI system tailored for clinical cerebrovascular imaging The proposed system will be the worldandapos s highest sensitivity and highest resolution tomographic MPI scanner In Phase I of this SBIR we will complete the main magnet design build a scale prototype and develop our manufacturing plan In Phase II we will construct the magnet and obtain phantom and animal images In Phase III we will perform animal and then human testing PUBLIC HEALTH RELEVANCE Magnetic Particle Imaging MPI is a new imaging modality whose unique contrast safety and speed solves several limitations and concerns of current neurovascular imaging protocols Mutagenic radiation kidney disease and brain damage has caused major concern and re evaluation on the use of CT angiography and MR angiography methods Here we propose to commercialize the first cerebrovascular MPI imager offering an alternative and new modality to allow safe assessment staging and monitoring of neurovascular diseases such as stroke aneurism and other vaso malformations Successful completion of a human brain MPI imager will mark the beginning of a new field of diagnostic imaging comparable in scope to the introduction of MRI CT or Ultrasound

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

8 SBIR/STTR records share this UEI (2015–2023). Reported award amounts total $10,100,200. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.