SBIR/STTR Research Award

Ultrasound Imaging of Breast by Use of a Hemispheric Array and Inverse Scattering

Award identifier a4daefe8c4a23458fe22ba5bf884d52d6aaace05c30a7d2eb2afd0544c12c58bAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$299,997

Program and phase

SBIR · Phase I

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
HABICO, Inc.
Proposal award date
2015-09-04
Contract end date
2017-02-28
UEI
NKLWGUVCN7M6
Solicitation number
PA14-071
Topic code
102

Research abstract

DESCRIPTION provided by applicant The long term objectives of this project are to develop a high performance cost effective clinical prototype of a unique breast imaging system HABIS that uses non ionizing ultrasound for examination of the breast and to demonstrate the medical value and clinical efficacy of the system through trials of the system in medical center and outpatient imaging center settings The immediate objectives in Phase I of this SBIR application are to confirm that HABIS meets acoustic and electrical safety requirements as well as expectations for resolution and to accumulate a portfolio of initial human subject images that will aid the planning of more extensive human trials in a later SBIR Phase II project The imaging system is designed to overcome x ray mammography limitations of poor resolution of contrast in dense breasts i e breasts with high x ray attenuation discomfort and anatomical deformation induced by compression and poor imaging of breasts with implants The system consists of a custom data acquisition apparatus a high performance computer network and novel software that controls the collection of data and forms volumetric images having isotropic high resolution m These images are reconstructions of sound speed and attenuation slope based on inverse scattering as well as aberration corrected b scans Unique features of the system are collection of scattering data from the entire breast volume in about two seconds without any moving parts to minimize image degradation from motion extrapolation of measured scattering to obtain virtual measurements in the opposite hemisphere where actual measurements are impossible to obtain directly and simultaneous independent reconstruction of subvolumes to speed the reconstruction process Phase I has four specific aims Conduct acoustic and electrical tests to confirm that HABIS is safe for patient use and secure approval for human imaging studies Quantify HABIS point and contrast resolution and confirm that resolution meets calculated expectations by using images of contrast and resolution phantoms Develop image acquisition and review protocols suitable for use by technicians and clinicians and optimize imaging algorithms to ensure efficient validation of data acquisition and clinical review of quantitative and b scan images Assemble a portfolio of HABIS images acquired from human subjects with normal as well as abnormal mammographic results that will be used to guide the development of a plan for extensive human trials in an SBIR Phase II project The major results of the Phase I aims would be proof that HABIS complies with standards for patient safety approval for human studies by an institutional review board quantified point and contrast resolution of HABIS optimized HABIS software suitable for patient imaging to be conducted by clinical collaborators and human subject images that will provide preliminary evidence of the medical value of HABIS and indicate questions to be addressed in SBIR Phase II human trials Achievement of the long term goals of this project would lay the foundation for additional studies that could change the present clinical paradigm of imaging for breast cancer detection diagnosis and monitoring of response to treatment PUBLIC HEALTH RELEVANCE HABIS a novel breast imaging system that uses a hemispheric ultrasound transducer array was developed as a research instrument by the Investigators The system uses more than transducer elements with independent and parallel acquisition channels to collect a complete set of pulse echo measurements of the breast in about two seconds without the need for mechanical translation of the transducers The measurements are rendered into volumetric b scan and quantitative images of the breast by a dedicated custom network of high performance computing nodes that perform on site the massively parallel computations needed for timely reconstructions These innovations allow breast imaging of unprecedented resolution with greatly reduced motion artifacts Extensive commercial activity in the area of breast imaging in general and ultrasound breast imaging in particular provides evidence of ample market opportunities for novel and superior imaging modalities Numerical simulations already support the theoretical medical advantages of HABIS The long term purpose of the proposed SBIR project is to provide clinical evidence of these theoretical advantages using extensive in vivo human imaging studies and to transform the research instrument into a commercially viable clinical imaging system The immediate objectives of the Phase I project are to confirm that HABIS meets patient safety requirements and expectations for resolution and to accumulate a portfolio of initial human images that will aid the design of more extensive human trials in a later SBIR Phase II project Successful completion of the overall project could significantly advance the state of breast cancer detection diagnosis and monitoring response to treatment

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.