SBIR/STTR Research Award

Design Optimization of a Non-degradable Synthetic Device for Cartilage Defects

Award identifier fc7fafca7e49aa02d8dcc5cd6516b049d069d0d311504274c237c2847190723dAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$209,224

Program and phase

SBIR · Phase I

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Hydro-Gen LLC
Proposal award date
2015-09-01
Contract end date
2016-09-30
UEI
LYXWVTDMH9D3
Solicitation number
PA14-071
Topic code
NIAMS

Research abstract

DESCRIPTION provided by applicant Trauma and overuse of joints can lead to painful defects in the articular cartilage and underlying bone which adversely affect the mechanical and biological function of the entire joint Over time this early stage damage can spread leading to end stage osteoarthritis OA While treatments for osteochondral defects have been developed to relieve pain and delay the spread of damage current solutions are perceived as unreliable requiring early surgical revision To better treat these defects we have developed an innovative non degradable off the shelf device that will provide immediate structural integrity to the defec site for the duration of implantation while also integrating with the host tissue The device is non cell based non biodegradable synthetic and porous and as such represents a significant shift in the current paradigm for the treatment of chondral and osteochondral defects The implant consists of a solid cylindrical poly vinyl alcohol PVA core to resist joint load concentrically surrounded by a porous PVA outer rim press fit with surrounding tissue and designed to integrate with cartilage with the solid core attached to a porous metal base for initial fixation and integration with bone The device is arthroscopically implanted into the defet in a dehydrated form which then rehydrates in situ to form a strong interface with the host tissue thus enabling immediate weight bearing While a series of in vitro and in vivo animal models have demonstrated that the device can integrate with host tissue and mechanically function much in the way of the native tissue we encountered several instances of mechanical failure of the device when the PVA disassociated from the metal base The objective of this study is to modify the PVA metal interface to prevent failures while maintaining the ability of th device to mechanically function in a loaded joint To this end we have used finite element models to direct modifications to i the macroscopic geometry of the PVA metal interface and ii the stiffness of the PVA metal interface Our goal is to determine which combination of changes in macroscopic interlock and PVA stiffness groups in total are robust enough to withstand sustained weight bearing First we will optimize the shear and tensile strengths of the PVA metal interface to avoid mechanical failure after device rehydration Specific Aim Secondly we will subject the device to repetitive axial and shear forces using a custom rolling sliding device to simulate the forces applied to the device in situ Specific Aim Optimized design criteria will be based on the maximum shear and tensile stresses at the PVA metal interface calculated in the FE model Aim and characterization of the fatigue properties of the device Aim Through this suite of tests we will identify the device design with the highest shear and tensile safety factor that is able to restore load distribution across the joint over extended cycles of loading The optimal design from this study will be subsequently used for re implantation into our previously established in vivo horse model PUBLIC HEALTH RELEVANCE Approximately million patients worldwide have been diagnosed with articular cartilage damage Despite this staggering number there is no reliable method to treat these painful injuries To address this serious clinical problem we have developed a non degradable off the shelf device that will provide immediate reliable structural integrity to the defect site for the duration of implantation while also integrating with the host cartilage and underlying bone to provide further fixation Our study will refine the design of this novel device to ensure that it is structurally sound while maintaining its ability to mechanically function much in the same way as the native cartilage thereby aiding in the transition of this technology into clinical care

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

2 SBIR/STTR records share this UEI (2015–2019). Reported award amounts total $1,705,828. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.