SBIR/STTR Research Award

A Fully Independent Real Time Treatment Verification System for Radiotherapy

Award identifier 60ffca7486db1f01013545d50ce4c50183868ce3b18ec5bc79040c7c639661efAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$279,563

Program and phase

SBIR · Phase I

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
SUN NUCLEAR CORP.
Proposal award date
2015-09-01
Contract end date
2016-02-29
UEI
NPL7NZRDALB3
Solicitation number
PA14-071
Topic code
102

Research abstract

DESCRIPTION provided by applicant Modern day radiotherapy has developed in complexity to the degree that significant treatment errors are both difficult to detect and difficut to completely avoid In the current day radiotherapy department it is common to have a large number of patients being treated with Intensity Modulated Radiotherapy IMRT techniques When treating patients with these techniques it can be difficult to detect patient setup errors and virtually impossible to detect beam collimation errors without the use of automated secondary checks Incorrect dose delivery or dose delivered to the wrong area is also an ongoing treatment risk Despite gains in the implementation of automated mechanisms for detection of errors the incidence of concerning treatment misadministrations is still significant Treatment delivery errors in the modern era have been reported by several authors as occurring during from to of patientsandapos courses of treatment While most of these are judged to not be of clinical importance the rate of significant treatment errors is still thousands of incidents per yar in the United States alone Compromised radiotherapy treatments can lead to lower control rates and or higher complication rates We will develop a system that will provide the radiotherapy clinic with the capability to completely and independently measure the geometric alignment and dosimetric compliance of an individual treatment fraction in real time as the patient is treated with any arbitrarily complex treatment technique The system will consist of a high density cloak of radiation detectors deployed in a ring centered on the treatment apparatus isocenter and within the rotational circle of the head s of the radiation delivery system The detector cloak will surround the area within the patient being treated and will measure the radiation fluence both entering and exiting the patient The dosimetric data acquired at the time of treatment will allow for the calculation of the complete dose distribution actually delivered to the patient for each and every treatment session The detection system will be physically and electronically independent of the treatment system thereby providing a truly comprehensive secondary monitor of the delivered dose Development and clinical deployment of a completely independent treatment verification system for radiotherapy has the potential to significantly reduce radiotherapy treatment errors The reduction of treatment delivery errors can increase local tumor control rates reduce the rate of treatment complications or both The ongoing compilation of actual treatment delivery compliance data will serve as invaluable confirmation of the benefit or lack thereof of newly implemented quality assurance techniques PUBLIC HEALTH RELEVANCE This proposed device will have a significant impact on public health It will catch human errors that heretofore go unnoticed where the errors range from minor to life threatening and it will document the entire treatment course thus providing essential data for quality improvement feedback Conservative estimates range from to of patients undergoing radiotherapy treatment may benefit from the reduction of errors that could be achieved with the implementation of a completely independent dosimetric monitoring system

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

7 SBIR/STTR records share this UEI (1985–2017). Reported award amounts total $3,562,774. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Environmental Protection Agency

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.