SBIR/STTR Research Award

Low Dose Rapid Scanning Slit Digital Mammography and Breast Tomosynthesis

Award identifier 84f05e3852921d233925bdbe5291dbc905f2e772501fcb743555dae7f385154bAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,496,748

Program and phase

SBIR · Phase II

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DXRAY, INC.
Proposal award date
2015-06-01
Contract end date
2017-07-18
UEI
Not reported
Solicitation number
PA13-088
Topic code
102

Research abstract

DESCRIPTION provided by applicant This fast track grant titled andquot Low Dose Rapid Scanning Slit Digital Mammography and Breast Tomosynthesisandquot will enable us to bring to market a clinically driven improved method of breast imaging based on photon counting x ray detector arrays with energy discrimination The detectors will enabled significant improvements in x ray breast imaging such as reduced patient dose while maintaining excellent image quality enhanced tissue contrast material decomposition capabilities tissue type identification and quantitative iodine contrast imaging The overall goal is to bring to the marketplace a photon counting energy dispersive x ray detector with energy discrimination for use in human breast imaging So far we have demonstrated a first generation fast photon counting x ray imaging array prototype which has a higher maximum output count rate by more than an order of magnitude than all others and the array has been used to generate the preliminary data Our technology is capable of counting at over counts per second cps per m pixel which is cps mm and is the highest output count rate OCR measured to date with x rays to our knowledge Our x ray imaging arrays are completely vertically integrated and can be tiled to large field of view We use this technology to develop scanning slit breast imaging with multiple stacked D high flux energy resolved single photon counting detector arrays For scanning slit digital mammography DM we have the advantage of energy information as compared to the currently available systems Whereas for scanning slit digital breast tomosynthesis DBT we would have in addition to energy information scatter rejection from the multi slit scanning Building a system capable of both DM and DBT in a scanning slit mode offers the chance to achieve DM DBT and synthetic DM from DBT data all on one system A gantry design will be used to sweep the detector slits across the FOV always close to and parallel to the compressed breast and always pointing to the focal spot for both DM tube at and DBT tube anywhere between so that the geometry of the projection images is the same as currently used in flat panel DM and BDT The high OCR allows the use of a strong mA x ray tube to produce shorter scan times The proposed photon counting x ray detector based breast imaging will not only improve the quality of the current attenuation based gray scale images but also open a door to completely new applications new procedures and new protocols using the capabilities of tissue type specific x ray images We expect large commercial success with this product This is due to the significant improvements to and advantages over existing detectors that our technology provides together with the widespread and increasing use of breast imaging The x ray exposure in breast cancer screening has been of major concern for radiologists and physicists as the number of examinations has increased Therefore a method which reduces the patient dose in screening examinations will have a significant impact on public health Our product addresses the need to reduce dose in breast imaging At the same time improved tissue differentiation and contrast specific identification is needed for better diagnosis Our product addresses these needs by improving image quality by making use of the energy information contained in the individually counted x rays at high flux information that is currently not obtainable with the non photon counting x ray imaging arrays currently in use in breast imaging systems PUBLIC HEALTH RELEVANCE We are developing fast energy resolved photon counting arrays for x ray imaging This new detector technology can potentially reduce dose and improve contrast when applied to breast imaging The detector can perform rapid scanning slit digital mammography and digital breast tomosynthesis The proposal submitted contains several innovative advancements to the current state of the art technologies employed in x ray imaging

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.