SBIR/STTR Research Award

Cellular Capacitance Monitoring Integration into Digital Patch Clamp Amplifier.

Award identifier 987d363793adec9c3fb7baf8c9c58e35f654fa21ee35c97a010695cfa8c6073cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$175,409

Program and phase

SBIR · Phase I

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ROKHAN LLC
Proposal award date
2015-03-01
Contract end date
2016-08-31
UEI
Not reported
Solicitation number
PA13-140
Topic code
105

Research abstract

DESCRIPTION provided by applicant Cell membrane capacitance is directly proportional to cell surface area This is true because membrane composition thickness and dielectric constant are invariant and not changed by differences in membrane protein density It is thus possible to monitor cellular capacitance fluctuations as a measure of cell surface area changes that occur with exo and endo cytosis events Rokhan LLC doing business as Neuroscience Tools has recently developed and commercialized the Digital Clamp One DCO the first patch clamp amplifier in which the incoming signal is digitized and digitally processed to calculate and generate the command signal to the cell Other commercially available patch clamp amplifiers are advertised as digital have digital data outputs and are controlled by a host computer so that they need have no knobs on the front panel However they still feedback and amplify the analog input to generate the analog command signal back to the cell The DCO provides digitally processed feedback that allows switching seamlessly from conductance clamp to voltage clamp to current clamp among other advantages offered by its dynamic digital feedback capabilities In Phase I we will add capability as a high resolution high speed cellular capacitance monitor displaying capacitance fluctuations in femtofarads to reveal small surface area fluctuations occurring during e g exo or endo cytosis in isopotential cells The instrument will generate a sinusoidal stimulus signal input superimposed on the command DC signal to the cell and employ an innovative algorithm in the time domain to calculate capacitance by fitting a sine wave with the same frequency as the stimulus to the acquired data The expected advantage of this novel approach are a high signal to noise ratio and the ability to accurately monitor cell capacitance with fast time resolution even when membrane conductance is changing Cellular capacitance may be measured as a point value in the picofarads range using the conventional means of whole cell voltage clamping but the measured value will be less than the actual whole cell capacitance unless the cell is isopotential which is the case only in small and round cells It has recently been shown that it is possible to obtain a much more accurate measurement of whole cell capacitance in non isopotential cells using current clamping rather than voltage clamping Golowasch et al Further it is proposed that the ratio of the two ways of measuring may give valuable additional information about the cell type under study In Phase II we will develop software to enable the DCO to provide a fast assessment of a cellandapos s capacitance by both voltage and current clamping methods The ratio between them is a heretofore mostly underappreciated metric for the basic cellular morphology of cells It will aid in identification of cell type and morphological changes during development and plasticity and to characterize stem cell maturity PUBLIC HEALTH RELEVANCE The proposed project will introduce and validate a novel algorithm for faster more accurate monitoring of cell capacitance fluctuations which are directly proportional to cell surface area Events of exocytosis or endocytosis cause fluctuations in cell surface area that occur with release or uptake of substances from or into cells The use of a new time domain algorithm is made possible by the speed of our digital feedback clamping amplifier the Digital Clamp One

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.