SBIR/STTR Research Award

Micro-technology Enhanced Pediatric & Adult Lens Capsulotomy Device

Award identifier f66e5846207e1e7ba38b0b0ddc0e68e07373e09268e5a418f332f9b47f34c4b6Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,430,239

Program and phase

SBIR · Phase II

Award year

2015

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Mynosys Cellular Devices, Inc.
Proposal award date
2015-01-01
Contract end date
2016-12-31
UEI
XSZ6HTF4MAW4
Solicitation number
PA14-071
Topic code
NEI

Research abstract

DESCRIPTION provided by applicant This project seeks to develop and obtain regulatory approval for an innovative microtechnology enhanced surgical device that solves a significant therapeutic bottleneck in the treatment of lens cataract in children and adults As the leading cause of childhood blindness lens cataract interferes with the optical performance of the eye and if untreated can result in lifelong deficits in visual perception or blindness Cataract surgey in adults with million plus cases per year is the most common surgical procedure in the United States that with the aging demographics will continue to add to our healthcare burden The first step in pediatric and adult cataract surgery is technically the most challenging and involves the creation of a hole in the thin lens capsule capsulotomy to provide access for the subsequent removal of the diseased lens and if needed the implantation of an artificial intraocular lens Due to the unique biomechanical properties of the immature lens capsule current adult procedures for creating the capsulotomy opening if applied to infants and young children only have a chance of success As a result pediatric cataract surgeons must make do using devices with tissue chopping functions originally designed for non cataract surgical uses resulting in suboptimal capsulotomies In adults capsulotomy complications manifest as approximately cases of capsule tears each year which mandate alterations in the surgical plan and produce less than ideal vision correction Recent studies show that perfectly sized and circular capsulotomies produced by femtosecond lasers potentially lead to better clinical and visual outcomes However femtolasers are extremely expensive for physicians to acquire and cost individual patients an additional $ out of pocket expense thus limiting the benefits of this technology to a small fraction of the million cataract surgery patients each year The overall goal of this project is to provide physicians with a low cost device that automatically delivers dimensionally perfect capsuotomies for all pediatric and adult patients undergoing cataract surgery In Phase I andamp II we developed an easy to use disposable capsulotomy device that uses a novel microscale tissue cutting technology to provide quick consistent capsulotomies across a range of surgical skills The device is based on a microfabricated cutting ring element housed within a collapsible elastomeric housing to produce precise capsulotomies on a millisecond time scale Our device is inserted through the standard mm corneal incision and re expands to produce a desired capsulotomy mm in diameter Under Phase IIB we will perform the FDA mandated certifications and testing required for device regulatory approval In particular we seek support for transferring the manufacturing of this innovative microtechnology enhanced capsulotomy device into a FDA certified production environment and the completion of pre clinical and clinical studies to meet FDA regulatory requirements PUBLIC HEALTH RELEVANCE This Phase IIB application seeks to develop and obtain regulatory approval for a microtechnology enhanced surgical instrument to aid in lens capsulotomy during cataract surgery and in particular the treatment of childhood blindness due to lens cataract Lens cataract is the leading cause of pediatric visual disability and cataract surgery in adults with million cases per year is the most commonly performed surgical procedure in the United States Cataract removal restores sight and improves the quality of life for both patients and their families The proposed device uses advanced mictotechnology to simplify and automate a technically challenging surgical task in both pediatric and adult cataract surgery

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

5 SBIR/STTR records share this UEI (2010–2017). Reported award amounts total $5,469,533. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.