SBIR/STTR Research Award

A rapid response detector system for intensity modulated proton therapy dosimetry

Award identifier edb487287e86a8689c72ced2acae7ff6cfce4ccce80f3b3aee77745fc9123aa5Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$883,250

Program and phase

SBIR · Phase II

Award year

2014

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
PHENIX MEDICAL LLC
Proposal award date
2014-09-15
Contract end date
2016-08-31
UEI
Not reported
Solicitation number
PA13-234
Topic code
NCI

Research abstract

DESCRIPTION provided by applicant In recent years there has been increased interest throughout the world in the use of proton radiation therapy for treatment of cancer and independent studies project a annual increase in the installed base The replacement of X ray therapy with proton therapy will have substantial long term benefit to patients due to greatly reduced long and short term toxicity side effects Such effects also have substantial costs associated with their treatment that may continue for many years after treatment Making the cost of delivering proton therapy cost competitive to that of X ray therapy not only makes a superior treatment mode available but will also result in substantial long term savings to health care providers The capital and operating cost of extant systems is a major limiting factor The procedure referred to as Spot Beam Scanning SBS where scanning of a small beam D spot voxel takes advantage of the physical properties of protons and provides the ultimate in tumor conformality is now rapidly being introduced for use in for dose delivery SBS eliminates the need for patient specific devices collimators and compensators that are both expensive to manufacture and add considerably to the time needed to deliver each dose to the patient thereby further reducing operating costs The SBS approach however is more sensitive to organ motion than traditional procedures To overcome this fast SBS of the target volume to greatly reduce dose delivery times into the millisecond ms time scale is optimal Phenix believes that fast scanning not only makes the SBS more suitable for treating moving targets but also enables faster dose delivery as needed for new prospective treatment protocols using protons such as lung tumors The increasing use of accelerators by vendors that deliver beam in short ms pulses places further challenges on detectors than can rapidly verify the area treated and the magnitude of the dose delivered to the tumor These dual challenges require detectors that can monitor both the position and dose delivered in real time and provide rapid feedback to the accelerator to modify further dose to be delivered as required None of the extant systems now available can satisfy these demands The Specific Aims in this grant application are to perform the research needed to further develop the use of a novel very fast gas scintillation technique to measure the dose delivered and the spot position on a sub millisecond time scale based on the prototype developed in Phase I PUBLIC HEALTH RELEVANCE Technological advances are fueling a new generation of cancer therapy based on scanning an energetic narrow proton beam with intensity adjustments at every step to deliver a radiation dose that conforms to an arbitrary shaped tumor more precisely than ever before reducing both the cost and the short and long term toxic side effects of the treatment The need to carry out lateral beam scans in time intervals much shorter than organ motion periods and to do so possibly with new accelerators that deliver the beam in microsecond long pulses demands continuous monitoring of dose delivery with detector capabilities beyond those of existing commercial dosimeters We aim to develop a new kind of cost effective dosimeter in which scintillation of a gas traversed by the beam will simultaneously provide the accuracy response speed and position resolution matched to the demands of these new treatment protocols

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.