SBIR/STTR Research Award

SoundTrak: A Data Acquisition and Analysis System for OSDB

Award identifier 7cc03f267f606db425e3ff4697d5de8d9b728a0223b5319c42e560f7fb1f73f5Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,475,333

Program and phase

STTR · Phase II

Award year

2014

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
BARRON ASSOCIATES, INC.
Proposal award date
2014-09-01
Contract end date
2016-08-30
UEI
C8FUKQKC9JB4
Solicitation number
PA13-235
Topic code
NICHD

Research abstract

DESCRIPTION provided by applicant Obstructive sleep disordered breathing OSDB is common in both children and adults and is recognized as having substantial health related consequences at all ages Laboratory polysomnography PSG is the gold standard for diagnosing OSDB but the procedure is not without problems Polysomnographic studies are complex invasive expensive not universally available and require an overnight stay in a sleep laboratory Additionally conventional signals used to detect air ow especially oral air ow are qualitative making it difficult to precisely quantify OSDB Furthermore in children discrete apneas or hypopneas are often not present instead there are long periods with high e ort high resistance breathing requiring very low esophageal pressures to generate air ow in a narrowed airway This high resistance breathing is difficult to detect using conventional PSG Published research by the proposing team has demonstrated that high frequency inspiratory sounds HFIS in the frequency range of kHz are a marker for the occurrence of OSDB and HFIS are generated when the upper airway is narrowed during sleep and acts as a resonant chamber in agreement with the physics of sound resonance in a cylindrical pipe It is emphasized that these HFIS are different from the low frequency andlt kHz sounds that describe typical snoring HFIS intensity can be analyzed quantitatively to determine the degree of airway narrowing and the pressure gradient across the airway Barron Associates and the University of Virginia UVA are developing the SoundTrak system a low cost sleep monitor for use in individualsandapos home environments to noninvasively ergonomically and automatically acquire and analyze HFIS data pertaining to OSDB The SoundTrak system will collect low and high frequency sound data via a microphone and a small highly portable computing base station Breathing movements will be measured using a wireless thoracic band enabling inspirations to be detected and the patientandapos s sleep sounds to be discriminated from other sources The thoracic band will also collect wireless electrocardiogram ECG body posture activity and skin temperature data and relay that information in real time to the SoundTrak base station The SoundTrak system will include a pulse oximeter to report oxygen saturation levels which are often helpful to and expected by physicians assessing OSDB The SoundTrak system will provide many advantages over currently available home sleep monitoring technologies as is described herein The Phase I effort along with other recent published work by the proposing team demonstrated the feasibility of using HFIS and thoracic monitoring as an alternative to PSG for diagnosing OSDB The central goal of the proposed e ort is to demonstrate the viability of in home HFIS studies in children and adults Traditional overnight laboratory PSG will be compared with in home sleep studies based on the easy to use noninvasive Phase II prototype SoundTrak system PUBLIC HEALTH RELEVANCE Products resulting from this research have strong potential to provide a more accurate and cost effective alternative to traditional polysomnography studies performed in sleep laboratories worldwide PSG may also fail to reproduce patientsandapos usual sleep habits since the patient must sleep in a new environment while being highly instrumented as such home studies using the SoundTrak system may provide more representative data for diagnosing OSDB Medicare recently announced that it will cover in home sleep diagnostics including those using the apnea hypopnea index as their main criterion a decision that underscores the relevance of the project and its viability in the marketplace

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

331 SBIR/STTR records share this UEI (1987–2025). Reported award amounts total $130,507,041. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Defense, Department of Health and Human Services, National Aeronautics and Space Administration, Department of Commerce, Department of Education, Department of Energy

Contractor profile

BARRON ASSOCIATES, INC.

Historical federal award activity, when published, is on that contractor profile. Matched by UEI only.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.