SBIR/STTR Research Award

High Efficiency TlBr Gamma-Ray Detector Module

Award identifier 69100f6211ff272e3ea7e84376d11545a4eb84c1ff21db2f8aeeb2bb52ac4c29Awarding agency Department of Homeland Security

Award amount

$999,808

Program and phase

SBIR · Phase II

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Homeland Security
Branch
Not reported
Recipient company
RADIATION MONITORING DEVICES, INC.
Proposal award date
2013-08-09
Contract end date
2015-07-31
UEI
SCKQA85YU4U4
Solicitation number
HSHQDC-12-R-00052
Topic code
12.1-005

Research abstract

The ideal semiconductor detector for nuclear monitoring should have good energy resolution, high detection efficiency, compact size, light weight, easy portability and low cost. In the proposed effort, we plan to develop a detector module for nuclear monitoring based on thallium bromide (TlBr), a wide band gap semiconductor that recently has shown great promise as a gamma-ray detector material. TlBr has a number of very promising properties. It has high density (7.5 g/cm3) and high atomic number constituents (81, 35), which promises high sensitivity. The electrical resistivity of the material is high (>1010 -cm) without deep level doping. Furthermore, the material melts congruently at a modest temperature (480 C) and does not undergo a phase change as the crystal cools to room temperature, which allows use of melt-based crystal growth approaches such as Bridgman and Czochralski to produce large volume TlBr crystals. The cubic crystal structure of TlBr also simplifies crystal growth and device processing. As a result of recent progress in purification, crystal growth and processing, TlBr detectors with mobility-lifetime (μ) products of mid 10-3 cm2/V for electrons and mid 10-4 cm2/V for holes has been achieved. This has enabled the development of TlBr gamma-ray spectrometers with thickness exceeding 1 cm. In fact, TlBr detectors fabricated at RMD have exhibited < 1 % energy resolution (FWHM) at 662 keV upon depth correction. These detectors were cooled to -20C to achieve stable operation. The goal of this Phase II project is to build a cooled, compact TlBr gamma-ray detector module using the 3-dimensional position-sensitive readout technology pioneered by the group at the University of Michigan. The key advancement is to develop a lower power charge sensing ASIC that can digitally sample the outputs of an array of preamplifiers. By sampling the preamplifier outputs, the induced charges on the detector electrodes can be obtained as a function of time, so that digital signal processing can be used to perform gamma-ray spectroscopy, to determine the depth of interaction of individual gamma-ray energy depositions, as well as to measure charge drift time, electric field distribution within TlBr and lifetimes of electrons and holes. The digital ASIC readout system will enable both fundamental research on TlBr detectors and practical operation to perform gamma-ray imaging and spectroscopy outside the laboratory. Since TlBr detectors can operate in a stable manner at 20C, power consumption of the digital ASIC system should be minimized so that the system can be cooled to required temperature using Peltier coolers. Such an efficient, high resolution, 3-D position sensitive detector module will find application in nuclear monitoring areas such as nuclear treaty verification, safeguards, environmental monitoring, nuclear waste cleanup, and border security. Nuclear and particle physics as well as astrophysics are other fields of science were gamma-ray spectrometers are used. The developed detectors should have the following advantages:  -Efficient detection of gamma-rays (better than CZT per unit volume)  -Energy resolution < 1% (FWHM) at 662 keV  -Lower cost than CZT-based system due to lower cost crystal growth

Technology keywords

Not reported

Research funding history

930 SBIR/STTR records share this UEI (1983–2026). Reported award amounts total $346,950,619. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration, National Science Foundation, Department of Homeland Security

Agency intelligence

Department of Homeland Security

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.