SBIR/STTR Research Award

New, Non-Invasive (No-Puff, No-Touch), Tonometry Method: Remote photonic IOP biomonitoring using the damping factor of transitional oscillations after terminating its stimulation by a sound wave.

Award identifier 099e5de220b096a514c3b6f6b008417b0dd73031f6b2285c81c3c56f884c333dAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$315,825

Program and phase

SBIR · Phase I

Award year

2025

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Eye C Better
Proposal award date
2025-09-01
Contract end date
2026-08-31
UEI
LN1FESJLGMN6
Solicitation number
PA24-246
Topic code
NEI

Research abstract

Project Summary/Abstract Glaucoma is a major source of irreversible blindness affecting more than 5 million Americans and costing the U.S. economy $2.86 billion/year. Current glaucoma treatments include frequent eye-contacting intraocular pressure (IOP) measurements requiring anesthetic eye drops and interpretation by trained healthcare professionals which introduces bias. Our methodology, Photonic IOP Biomonitoring (PIB), allows high- precision, non-contact, non-air puff, reproducible and semi-continuous IOP monitoring without clinician interpretation. PIB measures sound wave induced scleral oscillations by monitoring laser speckle patterns. Physical modelling with machine learning (ML) algorithms deduce IOP. Ultimately, our goal is miniaturization into monoculars or eyeglasses allowing patients to take real-time IOP measurements relayed to physicians for treatment recommendations and medication dispensing through a smart phone-based system. Aim 1: Develop a physical model to seed ML algorithms for IOP resolution, accuracy and repeatability. ML is seeded with a random initial state when no test subject knowledge is available. In contrast, a physical model based on Newton’s equations of motion indicates the value of a continuous variable (IOP) given physical parameter values characteristic of the test subject. Ultimately, a physical model would identify IOP without further ML class regression. PIB free from ML optimization eliminates the need for calibration and physician interpretation. Output of this physical model will seed simpler ML algorithms to achieve better resolution, accuracy and repeatability. Hypothesis 1a: Porcine eye PIB measurements can achieve resolution of ≤1 mmHg. Hypothesis 1b: Porcine eye PIB IOP measurements will yield accuracy and repeatability of 2 mmHg standard deviation or less. These hypotheses will be tested by measuring porcine eyes with IOP within the range of 5 mmHg up to 60 mmHg. Aim 2: Implement pupil monitoring: An eye position monitoring system will aid subjects in keeping their pupil directed at the pupil monitor. Deviations from this nominal position will turn off the laser and pause data acquisition. Hypothesis 2a: Monitoring eye position will improve patient safety. Hypothesis 2b: Temporal filtering of large deviations will improve measurement accuracy and repeatability. Feasibility will be assessed by 1) showing that light entering the porcine pupil cannot exceed a threshold below the standard safety criteria of 0.6mW, and 2) by showing that IOP prediction accuracy, precision and repeatability improves in pig eye tests by incorporating eye position data. Aim 3: Assess PIB Repeatability in Human Eyes: PIB tests of 30 healthy human eyes (15 healthy human subjects) in Phase I will inform the development roadmap in a subsequent Phase II trial. Hypothesis 3a: PIB repeatability in human eyes is equal to that of a comparable set of pig eyes Aim 4: Safety and Comfort: We will monitor for patient comfort and signs of corneal superficial punctate epithelial erosions or dryness. Hypothesis 3b: PIB will be found innocuous as evaluated by comparable or fewer adverse events than GAT and comparable or greater comfort.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.