TEPC Microdosimeter for LEO and Beyond

Award identifier e173297ad3fc54ee02e0672d639b3d063b6da761c5c0c359f65fe04ccb58d673Awarding agency National Aeronautics and Space Administration

Award amount

$99,160

Program and phase

SBIR · Phase I

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
National Aeronautics and Space Administration
Branch
Not reported
Recipient company
LVI Systems, Inc.
Proposal award date
2009-01-22
Contract end date
2009-07-22
UEI
Not reported
Solicitation number
Not reported
Topic code
X13.01

Research abstract

A new generation of Tissue Equivalent Proportional Counters (TEPCs) for micro-dosimetric measurements will be designed, incorporating recent advances in the electronics industry and a new detector configuration. The unit is projected to be 2.5x4.5x1 in, weigh less than 8 oz, and consume less than 100 mW of power. A detector configuration of thirteen half-inch spheres arranged in a 2-D array will be used - twelve connected together to form an equivalent spherical 1.74-inch diameter detector for measuring low fluence environments, and the thirteenth detector connected independently allowing measurements during high fluence periods when the larger detector would saturate (such as during solar particle events). The new electronics will continuously convert the detector data at 1 Mhz. Digital methods will allow both the setting of any threshold and the determination of event peaks, and allow more sophisticated signal processing to be used to reduce noise and eliminate micro-phonics. In addition, a bi-processing method of analyzing the detector signals will allow determination of dose by both integration method and peak method which can then be analyzed to provide accurate total dose readings for the events from the threshold to below 0.05 keV/micron. The spectra below several kev/micron is important as it can contain up to 40% of the total dose. The detector filled with pure propane will simulate a 2 micron site size. Two spectra will be stored each minute, and total integrated dose, dose above threshold, dose equivalent dead-time will be provided every second. The spectra will have 2048 channels at 1 keV/micron for each channel, to a maximum of 2047 keV/micron. The threshold for peak detection and analysis can be set anywhere from 0.4 to 20 keV/micron. The unit will be capable of measurement ranging from less than 100 nGy/hr to over 100 mGy/hr.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

National Aeronautics and Space Administration

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.