SBIR/STTR Research Award
A Real-Time, Portable Non-Invasive Monitoring System of Muscle Oxygen and pH in Trauma Patients
Award amount
$100,000Program and phase
STTR · Phase IAward year
2008Award details
- Awarding agency
- Department of Defense
- Branch
- Army
- Recipient company
- BAMBOO LLC
- Proposal award date
- 2008-07-31
- Contract end date
- 2009-02-28
- UEI
- Not reported
- Solicitation number
- 2008.A
- Topic code
- A08-T037
Research abstract
War fighters face increased risk in the post 9-11 era of expanding terrorist activity and urban military conflicts. The problem is compounded by complex modern urban areas and modern rules of engagement often preclude the use of wide area offensive tactics. Consequently dismounted forces are called to enter challenging hostile terrain in search of select enemy targets. Many of these respondents are injured or killed each year due to improvised explosive devices detonated from remote locations. War fighters injured by these explosions often have significant loss of blood that leads to shock, which results in inadequate organ perfusion and tissue oxygenation. Hemorrhage is therefore a major cause of soldier death in the modern day battlefield. Resuscitation from shock aims to correct the mismatch between available oxygen and the demands of critical organs. Accurate knowledge of partial oxygen pressure, the oxygen saturation, and the pH of the peripheral muscle tissue support a successful resuscitation procedure. Therefore, this project will develop technology for a miniature device able to measure these parameters. The proposed system will utilize ultra bright directive light emitters with narrow photon energy spread in the 660nm to 1050nm spectrum. Each sensing objective will be optimized on a 3-layer phantom using an artificial neural network classifier scheme already proven to extract very reliable signals from highly cluttered ultra wide band raw data. The artificial neural network training strategy will take into account issues such as inhomogeneous medium, variation of light intensities, lack of monochromatic light sources, and the relation between light absorption, scatter and reflections. Under ideal conditions, the accuracy is expected exceed 95%.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- Noninvasive Monitor for Muscle Oxygen and pH in Trauma Patients
- A Real-Time, Portable Non-Invasive Monitoring System of Muscle Oxygen and pH in Trauma Patients