Explore This Research Award in CaptureIQ
Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.
Award details
- Awarding agency
- Environmental Protection Agency
- Branch
- Not reported
- Recipient company
- AERODYNE RESEARCH INC
- Proposal award date
- 2007-05-01
- Contract end date
- 2009-05-31
- UEI
- HTMHV7AL9A86
- Solicitation number
- PR-NC-06-10459
- Topic code
- 06-NCER-P1
Research abstract
Acrolein (CH2 = CHCHO) is a toxic unsaturated aldehyde that has been classified by the U.S. Environmental Protection Agency (EPA) as a hazardous air pollutant (HAP) because of its adverse health effect, particularly on respiratory systems. There are both anthropogenic and natural sources of acrolein in the environment. Acrolein is produced by combustion sources (e.g., vehicle exhaust, prescribed agricultural burning, cigarette smoke) and industrial sources, including manufacturing facilities of wood products. There is, however, very limited data quantifying the emissions of acrolein from these sources. Also, there are few reports of the ambient levels in surrounding regions that may be impacted by these sources.
There is a need of air quality instrumentation for acrolein for routine air quality monitoring in urban areas for health effect assessment, and at specific sites for source assessment studies. EPA Region 10 has identified as a priority issue the development of a measurement technique for monitoring acrolein. EPA is under increased pressure to regulate hazardous air pollutants as required by the 1990 Clean Air Act. In the Phase I program, we demonstrated the feasibility of a quantum cascade (QC) laser-based system for acrolein measurement, offering fast response and high sensitivity (~1 ppbv, 1 sec). The instrument is based on Tunable Infrared Laser Differential Absorption Spectroscopy (TILDAS) using QC lasers. The QC-TILDAS method has distinct advantages over indirect detection methods. Infrared absorption is an absolute, highly specific technique. In the Phase I program, we identified the optimum spectral region for acrolein monitoring. We investigated and identified background suppression methods with chemical scrubbers to remove interferences from the acrolein measurements, critical to achieving sensitive acrolein detection. In addition, we conducted laboratory studies of ambient and source emissions of acrolein.
The objective of the Phase II project is to fabricate and demonstrate a fully functional, fast response, cryogen-free QC laser spectrometer to measure acrolein. The instrument will have compact size to fit in a rack mountable box and will be capable of long-term, autonomous operation in the field. It will be able to obtain sensitivities in the parts-per-billion (ppbv) range for source monitoring and sub-ppbv range for ambient conditions.
There is a need for commercially available air quality instrumentation for acrolein and other toxic air pollutants. The QC-TILDAS system to be built and demonstrated in this program will have wide commercial applications for both routine air quality monitoring and for source assessment of hazardous air pollutants.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
Research funding history
410 SBIR/STTR records share this UEI (1983–2025). Reported award amounts total $116,799,166. Reported amounts are not federal obligations.
Phases: Phase I, Phase II
Agencies: Department of Defense, Department of Energy, National Aeronautics and Space Administration, National Science Foundation, Environmental Protection Agency, Department of Commerce
Agency intelligence
Environmental Protection Agency
Back to SBIR/STTR Research Awards