SBIR/STTR Research Award

Field Medical Sterilizer to be used in Austere Environments

Award identifier 07b1c8064abd0e4cc183774cdb7f0e69556c1d53c10e0002c698aa6a751f22a1Awarding agency Department of Defense · Navy

Award amount

$70,000

Program and phase

SBIR · Phase I

Award year

2006

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Navy
Recipient company
PHYGEN, INC.
Proposal award date
2006-08-07
Contract end date
2007-05-07
UEI
F7MMVRB2GZD3
Solicitation number
2006.1
Topic code
N06-075

Research abstract

The current Navy steam autoclave used in the field is large, heavy, and obsolete. Spare parts are no longer available and it is not suited to today's austere environments. Replacing the autoclave sterilizer with a device using a similar means of sterilization will not meet the requirements of modern Medical Devices used for new surgical and exploratory procedures because these devices are constructed of materials that cannot tolerate 120 to 130 C temperatures. The autoclave is minimally portable because of heavy chamber design materials and the volume and weight of water required. The replacement device sterilizes using Low Temperature Discharge Plasma and requires only several milliliters of peroxide for each cycle versus approximately five gallons of distilled water with the autoclave. Power consumed by the replacement device is expected to require approximately 8 to 15% of that required by the autoclave and uses single phase 120/220 VAC or 24 to 28 VDC versus three-phase 220 VAC power. Sterilization occurs at ~55C over a period of 38 to 58 minutes. Weight can be reduced by 50 to 70%, based on final user requirements, resulting in at least a two fold portability improvement. BENEFITS: As a replacement for the Steam Method of sterilization, particularly in austere environments, Low Temperature Plasma Sterilization is ideal. The elimination of the need for water is one of the primary advantages over the current autoclave, and provides for reduced size and weight, increased ease of transportability, shorter set-up times and significantly less power consumption. In addition, Low Temperature Plasma Sterilization enables a broader range of heat sensitive materials and devices to be sterilized and provides a much safer environment for operators using the machine and touching sterilized product or chamber surfaces. Phygen will position the Plasma Sterilization Device as the “next generation solution” for medical sterilization. Commercial market applications that Phygen will pursue include: • Military field applications and base hospitals • Emergency response and disaster recovery applications • Inpatient hospitals • Outpatient surgical facilities and medical clinics • Medical device and instrument manufacturers • Reprocessors - third-party service companies that sterilize for reuse both multiple-use and single-use medical instruments.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

6 SBIR/STTR records share this UEI (2004–2008). Reported award amounts total $3,522,337. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Defense, Department of Health and Human Services

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.