Research abstract
Air particulates have been identified as sources of primary and secondary
health risks. More than 5,000 air particulate monitoring stations have
been established in the United States, mostly for measuring total mass and
size distribution. Real-time monitoring instruments for mass and size
distribution are commercially available today. The network of monitoring
stations performing chemical composition measurements is smaller. Samples
typically are collected on filters, which then are transported to laboratories
for analysis. This particularly is true for the monitoring of heavy metal
contamination, predominately performed using energy dispersive x-ray fluorescence
(EDXRF) analysis in laboratories. Even with a high-power (water cooling
needed), heavy, and expensive laboratory instrument, a long sampling time (typically
24 hours) is needed to achieve reasonable detection sensitivity.
X-Ray Optical Systems, Inc., (XOS) proposes to develop a unique EDXRF system
for real-time measurement and monitoring of elemental composition, particularly
heavy metal contaminants. The use of innovative x-ray optics in the proposed
system enables time-resolved measurements with significantly improved detection
sensitivity, achieving such performance in a low-power, compact, and automated
system.
In Phase I, XOS successfully demonstrated the performance of the proposed
approach by retrofitting the new x-ray optic technology into an existing particulate
monitoring system. Even with the non-optimized prototype, a detection
limit of 10 to 40 pg/m3 was achieved for Fe, Cu, Zn, Br, Sr, and Br with a
50 watt x-ray source and 8-hour sampling time. It was estimated that
this sensitivity was more than two orders of magnitude higher than that of
the conventional EDXRF method.
The ultimate objective of this Phase II research project is to develop a prototype
system capable of collecting samples and performing composition measurement
in a continuous and automatic operating mode. XOS expects to achieve
the equivalent detection limit of Phase I with 1-hour time resolution for transition
elements with a 50-watt system. The system, which can be configured
for PM2.5, PM10, or total suspended particulate, will be packaged as a field-deployable
instrument with the size, weight, and power consumption similar to those currently
deployed in U.S. Environmental Protection Agency networks.
Considering the proposed technology is unique and new, the initial market
may be research-oriented. This will provide the opportunity for the PM
monitoring community to review the technology and recognize its benefits. Once
accepted by the research community, XOS expects systems deploying the technology
to be widely distributed both in the United States and internationally.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
Research funding history
74 SBIR/STTR records share this UEI (1991–2011). Reported award amounts total $18,347,505. Reported amounts are not federal obligations.
Phases: Phase I, Phase II
Agencies: National Science Foundation, Department of Energy, Department of Health and Human Services, Department of Defense, Environmental Protection Agency, Department of Commerce
Agency intelligence
Environmental Protection Agency
Back to SBIR/STTR Research Awards