SBIR/STTR Research Award

Field Analytical Model for Perchlorate

Award identifier 64554fa12208d0538eee6986b7f601a79f570a4b3fa8cb2592f473376e7ceaa5Awarding agency Environmental Protection Agency

Award amount

$70,000

Program and phase

SBIR · Phase I

Award year

2006

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Environmental Protection Agency
Branch
Not reported
Recipient company
IA, Inc.
Proposal award date
2006-03-01
Contract end date
2006-08-31
UEI
Not reported
Solicitation number
PR-NC-05-10246
Topic code
05-NCER-D4

Research abstract

Perchlorate is a widely used component of solid fuel, missile and rocket propellants, explosives, and pyrotechnics. It has been shown to reduce iodide uptake into the thyroid gland. The U.S. Environmental Protection Agency (EPA) has found perchlorate contamination in 18 states and believes contamination may exist in as many as 39 states. In early January 2005, the National Academy of Sciences, in an EPA-sponsored study, recommended a reference dose (RfD) for human ingestion of 0.7 μg/kg/day, which suggests a maximum contaminant level (MCL) of 24.5 μg/L (ppb) or lower; several states allow between 1 and 6 μg/L. Based upon this recommendation, there is a need for field monitoring of perchlorate in ground and surface waters to test the effluent of remediation facilities and to determine soil cleanup levels. To provide a field analytical method, IA, Inc., has devised a technology that combines ion chromatography (IC), similar to that used in EPA Method 314, with specific perchlorate detection using a low detection limit ion selective electrode (ISE). Use of the perchlorate ISE as the detector results in lower interference from common anions than is found using Method 314. For this method, IA received a patent in 2004 (U.S. Patent No. 6,736,958). This method simplified and improved Method 314, as the ISE replaced both the conductivity detector and the suppression unit. It also improved the approach of measuring perchlorate by ISE, because the presence of sufficiently high levels of competing ions, measured without separation, can yield false positive results. The innovation of this Phase I research is to simplify and standardize electrode construction by casting the electrode on thin-walled, porous tubing after having defined free space. The objectives are to: (1) cast electrodes on a selection of porous tubing, selecting one that provides optimum robustness and reproducibility; (2) optimize electrode response by selecting the ionophore, plasticizer, and other ISE components; and (3) determine the selectivity obtained when using the perchlorate ISE as the detector for IC. Phase II will focus on optimizing calibration, developing analytical software, and field testing a prototype instrument. The resulting instrument will be suitable for field use, adaptable to batch analysis in the laboratory, and capable of remote sensing. Potential markets include U.S. Department of Defense contractors, environmental engineers and testing laboratories, state and municipal water authorities, and remediation firms.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Environmental Protection Agency

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.