SBIR/STTR Research Award

Ballistic Missile Innovative Radar and RF Products

Award identifier 4550ee80367b9410660329faf230138f92278a9a6de01dcb5c0074ba714506f7Awarding agency Department of Defense · Missile Defense Agency

Award amount

$69,539

Program and phase

SBIR · Phase I

Award year

2004

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Missile Defense Agency
Recipient company
Thermal Form & Function Inc.
Proposal award date
2004-02-10
Contract end date
2004-08-09
UEI
YWH8BFBN98J5
Solicitation number
2003.1
Topic code
MDA03-052

Research abstract

A pumped liquid two-phase cooling system is proposed for use in active radar thermal management systems. The technology pumps liquid refrigerant (R-134a) to offset strip fin heat exchangers that are in thermal contact with the power amplifier coldplates. The refrigerant evaporates and removes heat isothermally from active components. A two-phase mixture leaves the offset strip fin heat exchanger where it is condensed and returns to the pump inlet. Significant improvements in heat transfer coefficients, reduced pumping requirements, and isothermal operation are expected when compared to existing single phase thermal management systems in active radar applications. Two of the MDA radar systems that may benefit from this type of thermal management system are Theater High Altitude Area Defense (THAAD) program and X-Band Radar (XBR) program. Due to performance and reliability requirements, channel temperatures and the amplifier-to-amplifier temperature gradients must be kept low. Modifying the THAAD and XBR cooling systems to be pumped liquid two-phase systems will: 1) Increase thermal performance 2) Maintain isothermal operation 3) Reduce each system's flow rate, which will reduce the required pumping power and allow for smaller coolant distribution systems 4) Since R-134a is a dielectric fluid, a leak will not cause an electrical short circuit. High performance cooling of digital and power electronic components is applicable to many commercial market segments. The enterprise computer and server market in particular has been seeking cooling technologies to replace air cooled heat sinks in high density applications. The proposed pumped liquid two phase cooling technology has already been demonstrated to one large computer company and more have expressed interest. Pumped liquid two phase cooling has the potential to drive greater packaging densities while at the same time improve the cooling performance of servers and enterprise computers. In the power electronic segment of the commercial market, some applications are approaching the limit of single phase liquid cooling. Particularly, high power density motor controls could benefit from the high performance low pumping power of a pumped refrigerant two phase cooling system.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2004–2014). Reported award amounts total $1,510,882. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.