SBIR/STTR Research Award

Crystal Transducers for Harmonic Imaging

Award identifier 9bda7f8e0a78c4b1daad34ecd97f0b58c62fa814a6f7b85058bc22554856de86Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$746,540

Program and phase

SBIR · Phase II

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TRS CERAMICS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
PMYKUK6KNB75
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Contrast agent harmonic imaging has become a very important tool for studying blood perfusion. Due to the extensive amount of angiogenesis that occurs around malignant tumors, the use of ultrasound contrast agents has the potential to improve cancer diagnosis and to direct therapies. However, existing transducers are limited in their ability to form images from contrast agent harmonics because they lack sufficient bandwidth. This is especially true if both second and sub-harmonics are to be used to construct an image. In the Phase I program TRS Technologies, Blatek, Inc., J&W Medical, LLC, and Thomas Jefferson University Hospital demonstrated a solution to this problem by constructing a very broad band transducer using single crystal ferroelectric. This material (PbCMgi/sNb^CVPbTiOs - PMN-PT) has a very high electromechanical coupling coefficient (kss > 90%) so that ultrasound transducers constructed from it have an inherently broad bandwidth. In the Phase I program a single element, focused transducer was constructed from a crystal/epoxy 1-3 composite. The transducer had a bandwidth of 130% with excellent receive sensitivity at 9 and 2.25 MHz, the second and subharmonics, respectively, of the 4.5 MHz transmit frequency. Feasibility for contrast agent detection was demonstrated by using the transducer to measure the strength of 2nd harmonic signals generated by Sonazoid microbubbles in water. For the Phase II program, TRS proposes to build on these results by constructing a broad band single crystal linear array and using it for contrast agent enhanced imaging VX2 liver tumors in rabbits.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

129 SBIR/STTR records share this UEI (1991–2017). Reported award amounts total $37,410,092. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, National Aeronautics and Space Administration, Department of Health and Human Services, National Science Foundation, Department of Energy

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.