SBIR/STTR Research Award

ATLANTIC APPLIED RESEARCH CORPORATION HAS BEEN DEVELOPING A VERY HIGH ACCURACY LASER SURFACE SHAPE MEASUREMENT SYSTEM.

Award identifier a9806bff10cb639fbe9a7ffb4f9d1e92a09b4d2abd4ece75068c1a8db9062706Awarding agency Department of Defense · Air Force

Award amount

$49,943

Program and phase

SBIR · Phase I

Award year

1986

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Air Force
Recipient company
Atlantic Applied Research Corp
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

ATLANTIC APPLIED RESEARCH CORPORATION HAS BEEN DEVELOPING A VERY HIGH ACCURACY LASER SURFACE SHAPE MEASUREMENT SYSTEM. IT CURRENTLY HAS THE ABILITY TO SCAN A MEASUREMENT LASER BEAM IN ONE DIMENSION AND MEASURE THE POSITION OF THE SURFACE OF ALMOST ANY OBJECT IT STRIKES RELATIVE TO A REFERENCE PLANE. THIS NON CONTACT LINEAR DISPLACEMENT SENSOR PROJECT WOULD INVOLVE ADAPTING THE SCANNING MECHANISM SO THAT THE LASER BEAM WOULD BE DIRECTED ALTERNATELY AT THE PROBE AND AT THE MODEL'S SURFACE TO MEASURE THE DISTANCE BETWEEN THEM. COMPUTER PROGRAMS WOULD BE DEVELOPED TO ACQUIRE AND STORE THE POSITION DATA. THE SCANNING SYSTEM, INCLUDING THE LIGHT SOURCE AND RECEIVING PHTO DETECTOR WOULD BE LOCATED SEVERAL FEET FROM THE MODEL, OUTSIDE OF THE MACH 6 WIND TUNNEL. IT WILL OPERATE BY PASSING THE LIGHT THROUGH A WINDOW IN THE TUNNEL WALL. THUS THE HIGH INTERNAL TEMPERATURE IS NOT A PROBLEM. FOR PROBE AND MODEL SURFACES WHICH ARE DIFFUSE REFLECTING SURFACES, IT IS NOT NECESSARY TO ALIGN THE LASER BEAM NORMAL TO THE SURFACES BUT ONLY KNOW THE INCIDENCE ANGLE, SINCE THE SYSTEM USES A RANGE FINDING TECHNIQUE. A MINOR CORRECTION TO THE SPEED OF LIGHT DUE TO THE TEMPERATURE AND DENSITY OVER THE REGION BETWEEN THE PROBE AND THE MODEL MAY BE REQUIRED. THE SENSITIVITY OF THIS CORRECTION WILL BE INVESTIGATED. A DEPTH OF FIELD OF A 20 CENTIMETERS IS PRACTICAL. THE VERSATILITY OF THE SCANNING SYSTEM ALLOWS THE USE OF A SIMPLE SCANNER TO MEASURE MORE THAN ONE PROBE, IF DESIRED.

Technology keywords

Not reported

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.