SBIR/STTR Research Award

SPECTROSCOPY OF BRAIN ENERGY STATE AND OXYGEN DELIVERY

Award identifier b2d73749cba1eb5e73a7ee623d70173e56639baf4676b657945af8cfb5e98291Awarding agency Department of Health and Human Services

Award amount

$500,000

Program and phase

SBIR · Phase II

Award year

1989

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Not reported
Recipient company
INFRASCAN INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
G7ACQJPGP7U5
Solicitation number
Not reported
Topic code
Not reported

Research abstract

THE CONCURRENT EVALUATION OF BRAIN ENERGY STATE AND OXYGEN DELIVERY PROVIDES A UNIQUE APPROACH TO "EARLY WARNING" OF HYPOXIC/ISCHEMIC STRESS. NEAR INFRARED SPECTROSCOPY OF OXYGEN DELIVERY BY HEMOGLOBIN GIVES AN APPROXIMATION TO THE OXYGENATION OF THE CAPILLARY BED OF THECORTICAL LAYERS OF THE NEONATE BRAIN. SPEED OF RESPONSE OF THE OPTICAL METHOD IS HIGH (.1 SEC OR LESS), AND APPROPRIATETO SUDDEN CHANGES OF OXYGEN DELIVERY, FOR EXAMPLE, IN APNEA. HOWEVER, THE RELATIONSHIP BETWEEN OXYGEN DELIVERY AND ENERGY METABOLISM IS UNCERTAIN. PHOSPHORUS MAGNETIC RESONANCE SPECTROSCOPY GIVES PRECUSE AND CRITICAL INFORMATION OF THE ENERGY STATE OF THE BRAIN IN TERMS OF THEPHOSPHOCREATINE/PHOSPHATE RATIO, WHICH IS IN TURN RELATED TOTHE PHOSPHATE POTENTIAL (ATP/ADP X P(1)) (1). THE NMR METHOD IS NOT FAST, 5 MINUTES MAY BE REQUIRED FOR A DEFINITE VALUE, AND THUS, CANNOT SERVE AS A FAST "EARLY WARNING" OF HYPOXIC DISTRESS. THE DEVICE PROPOSED COMBINES TRANSCUTANEOUS INFRARED SPECTROSCOPY OF OXYGEN DELIVERY AS ARAPIDLY RESPONDING EARLY WARNING TOGETHER WITH PMRS AS A SLOWER, BUT MORE PRECISE, QUANTITATIVE EVALUATION OF DANGER. THESE TWO DEVICES IN COMBINATION CAN BE USED FOR THE INITIATION OF AGGRESSIVE THERAPY BY MANUAL AND AUTOMATICCONTROL OF THE OXYGEN DELIVERY TO THE BRAIN. THIS PHASE I APPLICATION HAS TO DO WITH TESTS OF SIMPLIFIED SPECTROPHOTOMETRIC TECHNIQUES FOR MEASUREMENT OF CAPILLARY BED OXYGENATION OF HEMOGLOBIN. TWO DEVICES ARE DESCRIBED, ONE EMPLOYING HOLOGRAPHIC GRATING MONOCHROMATORS AND THE OTHER TIME-SHARING INTERFERENCE FILTER SPECTROPHOTOMETRY. PHASE II DEVELOPMENTS INCLUDE DISPERSIVE DETECTOR SYSTEMS.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

21 SBIR/STTR records share this UEI (1988–2021). Reported award amounts total $5,935,835. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.